5. Maintenance

No maintenance is required, as long as the unit is used as intended within the specified
conditions.

6. Installation

6.1 Mounting /Removal

!
Before mounting or removing the unit:
Prevent damage to internal electronics from electrostatic discharges (ESD)
by discharging your body to a grounding point (e.g. use of wrist strap).
Prevent access to hazardous voltages by disconnecting the unit from AC/DC
mains supply and all other electrical connections.
Mounting
This unit should be mounted on 35 mm DIN-rail which is
horizontally mounted on a wall or cabinet backplate.
This unit uses convection cooling.To avoid obstructing the air
flow around the unit, use the following spacing rules. Minimum
spacing 25 mm (1.0 inch) above/below and 10 mm (0.4 inches)
left/right the unit.
Snap on mounting, see figure.
Min
10 mm
Removal
Press down the black support at the back of the unit
using a screwdriver, see figure.
6642-2200
Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
25 mm
25 mm
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles
7