16) Evacuate the system, and charge it with refrigerant. See the Nameplate for the
required refrigerant charge.
15) Connect the Terminals to the Compressor, and replace the Terminal Cover in its correct
position.
17) Replace the panels in their correct positions.
18) Plug in the ice dispenser.

4. REMOVAL AND REPLACEMENT OF DRIER

Always install a new Drier every time the sealed refrigeration system is
opened. Do not replace the Drier until after all other repair or replacement
has been made.
1) Unplug the ice dispenser.
2) Remove the panels.
3) Recover the refrigerant and store it in an approved container.
4) Remove the Drier using brazing equipment.
5) Install the new Drier, in the direction of the refrigerant flow. Use nitrogen gas at the pressure
of 0.02 - 0.03 MPa (0.2 - 0.3 kgf/cm
6) Check for leaks using nitrogen gas 0.98 MPa (10 kgf/cm
7) Evacuate the system, and charge it with refrigerant. See the Nameplate for the required
refrigerant charge.
8) Replace the panels in their correct positions.
9) Plug in the ice dispenser.
IMPORTANT
2
G) when brazing.
43
2
G) and soap bubbles.