Siemens SIPROCESS GA700 Operating Instructions Manual page 145

Continuous gas analysis
Hide thumbs Also See for SIPROCESS GA700:
Table of Contents

Advertisement

Article number
Name
A5E41276808
Analyzer chamber
A5E41276884
Analyzer chamber
A5E41276950
Analyzer chamber
A5E41276984
Analyzer chamber
A5E41277059
Analyzer chamber
A5E41277092
Analyzer chamber
A5E41277169
Analyzer chamber
A5E41277263
Analyzer chamber
A5E41277536
Analyzer chamber
A5E41277563
Analyzer chamber
A5E41277800
Analyzer chamber
A5E41277982
Analyzer chamber
A5E41277992
Analyzer chamber
A5E41278138
Analyzer chamber
A5E41278169
Analyzer chamber
A5E41278180
Analyzer chamber
A5E41278203
Analyzer chamber
A5E41278401
Analyzer chamber
A5E35263887
Cover
A5E35263542
Cover
A5E41946985
Cover
A5E41946993
Cover
A5E35263362
Socket
Table A-15
Spare parts list ULTRAMAT 7 - receiver chambers
Article number
Name
A5E35263502
Receiver chamber
A5E35263503
Receiver chamber
A5E36528448
Receiver chamber
A5E36528449
Receiver chamber
A5E36528452
Receiver chamber
A5E36528454
Receiver chamber
A5E36528456
Receiver chamber
A5E36528458
Receiver chamber
A5E43470307
Receiver chamber
A5E48644456
Receiver chamber
A5E48644474
Receiver chamber
Rack-mounted device
Operating Instructions, A5E31874006-12
Description
6 mm Al, flow-type, cleaned for O
6 mm Al FFKM, flow-type, cleaned for O
20 mm Al, non-flow-type, cleaned for O
20 mm Al+Ta FFKM, non-flow-type, cleaned for O
20 mm Al, flow-type, cleaned for O
20 mm Al+Ta FFKM, flow-type, cleaned for O
60 mm Al, non-flow-type, cleaned for O
60 mm Al+Ta FFKM, non-flow-type, cleaned for O
60 mm Al, flow-type, cleaned for O
60 mm Al+Ta FFKM, flow-type, cleaned for O
90 mm Al, non-flow-type, cleaned for O
90 mm Al+Ta FFKM, non-flow-type, cleaned for O
90 mm Al, flow-type, cleaned for O
90 mm Al+Ta FFKM, flow-type, cleaned for O
180 mm Al, non-flow-type, cleaned for O
180 mm Al+Ta FFKM, non-flow-type, cleaned for O
180 mm Al, flow-type, cleaned for O
180 mm Al+Ta FFKM, flow-type, cleaned for O
For analyzer chamber lengths 0.2 mm - 6 mm
For analyzer chamber lengths 20 mm - 180 mm
For analyzer chamber lengths 0.2 mm - 6 mm, cleaned for O
For analyzer chamber lengths 20 mm - 180 mm, cleaned for O
Mounting for analyzer chamber
Description
CO
CO
2
CH
4
C
H
2
4
SO
, C
H
2
4
10
NO
N
O
2
NH
3
CO highly selective
CO
with vibration compensation
2
CO
with vibration compensation
2
A.5 Spare parts/accessories
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Appendix
Classifica‐
tion
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
Classifica‐
tion
2
2
2
2
2
2
2
2
2
2
2
145

Advertisement

Table of Contents
loading

Table of Contents