Installation Position; Required Measurement Route - TESTO 0699 6446 Series Instruction Manual

Compressed air counter
Table of Contents

Advertisement

5.3.1

Installation position

Do not install the electronic sensor assembly in the crossed-out installation
positions shown in the following graphic. In the event of a limited flow, the
specified accuracy cannot be maintained.
The arrow shows the direction of flow for the medium.
5.3.2

Required measurement route

Bear in mind the required inflow and outflow routes in order to achieve the
specified measurement accuracy. The inflow route refers to the pipeline
length in front of the mass flow sensor and the outflow route to the pipeline
length behind the mass flow sensor, as seen in the direction of flow for the
medium.
Total
measuremen
Outflow
Inflow
t
stretch
=
Inflow
= 5
×
route
D
= 15
×
D +
route
B
90° elbow
two 90° elbows
one level
two 90° elbows
two levels
Valve, slider
route
+
Outflow
route
D = pipe diameter [mm]
B = total stilling pipe
B = 5 x pipe diameter (D)
B = 10 x pipe diameter (D)
B = 15 x pipe diameter (D)
B = 35 x pipe diameter (D)