CONFIGURATOR

WRL
Field
Description
1,2,3
WRL
Size
4,5,6
200, 400, 500
7
Operating field
° Standard mechanic thermostatic valve (1)
X Electronic thermostatic expansion valve (2)
Y Low temperature mechanic thermostatic valve (3)
8
Model
° Heat pump reversible on the water side
E Evaporating unit
9
Version
° Standard
10
Heat recovery
° Without heat recovery
D With desuperheater (4)
11
Integrated hydronic kit, source side
° Without hydronic kit
U Pump high head
V 2-way modulating valve
12
Integrated hydronic kit, user side
° Without hydronic kit
N Pump high head
13
Field for future development
° Field for future development
14
Soft-start
° Without soft-start
S With soft-start (5)
15
Power supply
6 230V ~ 3 60Hz with magnet circuit breakers
7 460V ~ 3 60Hz with magnet circuit breakers
8 575V ~ 3 60Hz with magnet circuit breakers
9 208V ~ 3 60Hz with magnet circuit breakers
(1) Water produced up to +39.2 °F
(2) Water produced up to +39.2 °F. For different temperature please contact the factory.
(3) Water produced from 39.2 °F up to 17.6 °F
(4) With this option the "Y" valve is not compatible.
(5) Only for supplies 460V ~ 3 60Hz and 575V ~ 3 60Hz

ACCESSORIES

AER485P1
RS-485 interface for supervising systems with MODBUS protocol.
AERNET
In Master operating mode, it can be used to remotely control up to
six devices configured as slaves with an RS-485 serial connection.
Remote control is available via PC, tablet or smartphone thanks to a Cloud Server
connection.
Chronological recording of the activities of the connected units (log files) is also
available for post analysis.

ACCESSORIES COMPATIBILITY

WRL
AER485P1
AERNET
PGD1
VT
28
200
400
500
9
9
15
WRL-H
Field
Description
1,2,3
WRL
Size
4,5,6
200, 400, 500
7
Operating field
° Standard mechanic thermostatic valve (1)
X Electronic thermostatic expansion valve (2)
8
Model
H Reversible heat pump, gas side
9
Version
° Standard
10
Heat recovery
° Without heat recovery
11
Integrated hydronic kit, source side
° Without hydronic kit
U Pump high head
V 2-way modulating valve
12
Integrated hydronic kit, user side
° Without hydronic kit
N Pump high head
13
Field for future development
° Field for future development
14
Soft-start
° Without soft-start
S With soft-start (3)
15
Power supply
6 230V ~ 3 60Hz with magnet circuit breakers
7 460V ~ 3 60Hz with magnet circuit breakers
8 575V ~ 3 60Hz with magnet circuit breakers
9 208V ~ 3 60Hz with magnet circuit breakers
(1) Water produced up to +39.2 °F. Option not available only for sizes 200 and 400.
(2) Water produced up to +39.2 °F. For different temperature please contact the factory.
(3) Only for supplies 460V ~ 3 60Hz and 575V ~ 3 60Hz
PGD1
This allows chiller command operations to be implemented from a distance.
VT
Anti-vibration mounts to be assembled under the unit's sheet steel base.