1.1. TOOLS AND PARTS.................................................................2
1.2. SYSTEM REQUIRMENTS..........................................................2
1.3. LOCATION REQUIREMENTS...................................................2
1.4 MINIMUM WATER VOLUME....................................................2
1.5. MINIMUM CLEARANCE.........................................................2
1.6 ELECTRICAL REQUIREMENTS.................................................3
2.1 HYDRONIC CONNECTIONS.................................................4
2.2. ELECTRICAL CONNECTIONS...............................................5
2.2.1CABLE.............................................................................5
2.2.2. CONNECTING POWER SUPPLY........................ .................5
4.1. PREPARATION FOR COMMISSIONING..................................6
4.2. MACHINE COMMISSIONING..................................................7
4.3. SEASON CHANGOVER...................................................................7
GENERAL WARNING FOR THE INSTALLER
The chiller must be installed by a qualified and trained technician. 
AERMEC will not assume any responsibility for damage due to failure to follow these instructions. Before beginning any operation, READ THESE 
INSTRUCTIONS CAREFULLY AND CARRY OUT THE SAFETY CHECKS TO REDUCE ALL RISK OF DANGER TO A MINIMUM. All the staff involved must 
have thorough knowledge of the operations and any dangers that may arise at the moment in which the installation operations are carried out. 
 
 
Vers. 1.1.15 
     
ANK INSTALLATION MANUAL
NORTH AMERICAN REVISION

Table of contents

 
.............................2
...............................4
.......................6
........................6
 
5.1. SET POINT IN COOLING MODE.....................................7
5.2. SET POINT IN HEATING MODE.....................................7
5.3. COMPRESSOR START-UP DELAY.....................................7
5.4. CIRCULATION PUMP...................................................7
5.5.FAN SPEED CONTROL..................................................7
5.6. ANTI-FREEZE ALARM.........................................................7
5.7. WATER FLOW RATE ALARM............................................8
....................................................8
6.1. HYDRAULIC CIRCUIT..........................................................8
6.2. ELECTRICAL CIRCUIT CHECKS......................................8
6.3. COOLING CIRCUIT CHECKS............................................8
6.4. MECHANICAL CHECKS................................................8
6.5.REFRIGERANT LOAD PROCEDURE.................................8
7. LIST OF CONTROLS........................................................9
WIRING DIAGRAM
..........................................................12
............................................................................13
..........................................11

Advertisement

Table of Contents
loading

Summary of Contents for AERMEC ANK

  • Page 1: Table Of Contents

    ANK INSTALLATION MANUAL NORTH AMERICAN REVISION Table of contents     5. OPERATION 1. INSTALLATION REQUIREMENTS   …………………..….2 5.1. SET POINT IN COOLING MODE……………………………..7 1.1. TOOLS AND PARTS…………………………………………………...…..2 5.2. SET POINT IN HEATING MODE……………………………..7 1.2. SYSTEM REQUIRMENTS…………………………………………..……..2 5.3. COMPRESSOR START-UP DELAY………………………...…..7 1.3.
  • Page 2: Installation Requirements

    1.2 SYSTEM REQUIREMENTS: possible icing from defrost condensate.  Aermec heat pump system are derived from actual laboratory   testing of the equipment. It is recommended that all deisgn criteria  Avoid placing the heat pump near areas such as sleeping  be met or exceeded to ensure proper operation and  quarters or study rooms. Normal operating sound levels may  efficient performance.  be objectionable if the heat pump is placed near certain   The designed system criteria are listed in the heat pump  rooms. A shift in sound type does occur during the defrost    unit specification sheets and in the heat pump technical man‐ mode. The defrost mode generally lasts no longer than 5 ual  minutes     This heat pump has been factory charged with a quantity of  refrigerant (R410A)   1.4 MINIMUM WATER VOLUME   IMPORTANT: Refer to “Aermec System Water Volume Guide” (you can download it on aermec.us in tutorial books section)   ANK heat pumps need a minimum volume of 35 gallons of water/glycol. If the version is an HA it has an internal 25  gallon tank so the system must contain a minimum of 10 additional gallons when all  zones but the smallest are closed or  not operating. (Only count the smallest zone volume along with the pipes to the manifold.     If the heat pump does not have an internal buffer tank you must add 35 gallons in the system with a buffer tank or  piping.   1.5 MINIMUM CLEARENCE 2  ...
  • Page 3: Electrical Requirements

    1.6 ELECTRICAL REQUIREMENTS   IMPORTANT:  Electrical wiring, disconnect means and over current  protection are to be supplied by the installer. Refer to the  rating plate for the maximum over current protection,  minimum circuit ampacity, and operating voltage. See wiring  diagram.   Install an adequately sized branch circuit disconnect, per the  NEC, within sight of and readily accessible from heat pump.   The cable or conduit and fittings connected from the  disconnect to the heat pump shall be rated for outdoor use.     Check the heat pump rating plate and follow the appropriate instructions below.    NOTE: All wiring must be suitable for outdoor use. Use copper  conductors only.   All field wiring must be done in accordance with National  Electrical Code requirements, applicable requirements of UL,  or local codes, where applicable.       Electrical wiring, disconnect means and over current  protection are to be supplied by the installer. Refer to the         rating plate for the maximum over current protection,  minimum circuit ampacity, and operating voltage. See wiring         diagram. current         3  ...
  • Page 4: Installation Instructions

    2 INSTALLATION INSTRUCTIONS This heat pump is shipped in one package, completely  assembled and wired. The indoor controller is shipped in a separate  ANK 030‐045‐050 H‐HP  carton when ordered.  1. Check the heat pump rating plate to confirm specifications  are as ordered.  2. Upon receipt of equipment, carefully inspect it for possible  shipping damage. Take special care to examine the unit  Air vent  inside the carton if the carton is damaged.  If damage is found, it should be noted on the carrier’s freight bill.  Damage claims should be filed with the carrier immediately.  Claims of shortages should be filed with the seller within 5 days.  NOTE: If any damages are discovered and reported to the carrier,  do not install the unit because your claim may be denied.  2.1 HYDRONIC CONNECTIONS  Water / glycol piping must be connected by a licensed, or certified   technician using established procedures.  IMPORTANT:  ANK 030‐045‐050 HA   Connecting water lines must be clean, properly sized     (minimum 1 ¼ inch). Reducing fitting shall not be used  Air vent   Use care with the water / glycol lines during the installation  process. If pex is used it can be cut by sharp objects.   Do not remove the caps from the lines or system connection  points until connections are ready to be completed.   1. Route the supply and return lines from the fittings on the  indoor manifold or tank to the fittings on the heat pump. Run   the lines in as direct a path as possible avoiding unnecessary   turns and bends.  Air vent ...
  • Page 5: Electrical Connections

     length   type of cable   absorption of the unit and the physical location   ambient temperature.  ATTENTION: Check the tightening of all power wire clamps on commissioning  and after 30 days from start‐up. Subsequently, check the tightening  of all the power clamps every six months. Loose terminals can cause   The ANK heat pumps are completely wired at the  overheating of the cables and components.  factory  a nd only require connection to the electrical  2.2.2 CONNECTING POWER SUPPLY mains, downstream from a unit switch, according  to that envisioned by the Standards in force on  this subject in the country of installation.   Before connecting the unit to the power supply mains , en‐   sure that the switch is off  It s also advised to check the following:   The electrical mains features are suitable   Open the front panel  For the absorption values indicated in the   ...
  • Page 6: Terminal Board Connections

    TO ACTIVATE TERMITAL BOARD 13POLE To activate terminal board set value of 9 PAN to 3. To get to this  parameter enter password 030.  SUMMER/WINTER REMOTE CONTROL (C/F) To prepare a summer/winter remote switch‐over device connect  the device contact to the clamps 3 and 5 of the 13 POLE terminal  board.   ON/OFF CONTROL (IA) To prepare an ON/OFF remote switch‐over device connect the de‐   vice contact to clamps 4 and 5 of the 13 POLE terminal board.   REMOTE ALARM (AE) 3. TERMINAL BOARD CONNECTIONS Remote indicator can acknowledge alarms, this is possible using  Connections under the responsibility of the installer clamps 6 and 7 of the 13 POLE terminal board, connect  an  acoustic or visual alarm signal device.   All connections to which reference is made in the following explanations  REMOTE PANEL (TRA) are part of the 13 POLE removable terminal board situated inside the ...
  • Page 7: Machine Commissioning

    5.6. ANTI-FREEZE ALARM The anti‐freeze alarm is never active if the machine is off or in stand ‐by mode. In order to prevent breakage of the plate heat exchanger  SEASON CHANGEOVER FROM PR3 due to freezing of the water it contains, the MODUCONTROL  stops  Just act directly on the switch. The machine switches  off automatically‐ the compressor if the temperature detected by the probe postioned  and switches back‐on with the selected functioning mode. Advance based  at the outlet  of the heat exchanger and in inlet to the chiller is  on the timeframe for the completion of works  for the system. Prior to  below +4°C/39°F.   the work to be carried out by the AERMEC service personnel, all other  THIS ANTI‐FREEZE SET TEMPERATURE CAN ONLY BE VARIED  BY AN  works (electrical and hydraulic hook‐ups, priming and bleeding of air  AUTHORISED AFTER‐SALES CENTRE AND ONLY AFTER HAVING CHECKED  from the system) must have been completed.  THAT THERE IS ANTI‐FREEZE SOLUTION IN THE WATER SYSTEM.    The intervention  of this alarm determines compressor stop  and not pump block, which remains active along with the switch‐on  7   of the  resistance if installed. To restore normal functions the tem‐ ...
  • Page 8: Water Flow Rate Alarm

    perature of the outlet water must rise above +4°C/39°F.  Rearm is man‐ − Carry out the appropriate checks on the filter dryer to check effi‐ ual.  ciency  6.4. MECHANICAL CHECKS WHENEVER THIS ALARM INTERVENES, WE ADVISE YOU CALL THE NEAR‐ EST AFTER‐SALES SERVICE IMMEDIATELY. − Check the  ghtening of the screws the compressors and the elec‐ 5.7. WATER FLOW RATE ALARM trical box, as well as the exterior panelling of the unit. Insufficient  fastening can lead to undesired noise and undesired vibrations  The MODUCONTROL manages a water flow rate alarm controlled by the  differential pressure switch installed in series on the machine. This type  − Check the condi on of the structure. If there are any oxidised  of safety device intervenes after the first 40 seconds of pump function‐ parts, treat with paint suitable to eliminate or reduce oxidation.  ing, if the water flow rate is not sufficient. The intervention of this alarm  6.6. REFRIGERANT CHARGING PROCEDURE determines compressor and pump block.   IT IS forbidden to CHARGE the circuit with a  6. MAINTENANCE refrigerant gas different to the one indicated.  Using a different refrigerant gas can cause  Inspection, maintenance and eventual repair work  serious damage to the compressor.  must be carried out only by a legally qualified techni‐ cian.   The charging procedure is the following:  Lack of control/maintenance can cause damage to ...
  • Page 9: List Of Controls

    7. LIST OF CONTROLS FOR THE GUIDED   PROCEDURE How to modify a parameter in the installer menu:  How to modify a parameter in the user menu:  To enter the INSTALLER menu, press the key shown in (Fig.A).Once the  To enter the USER menu press the key shown in (Fig.A). Once the key  key has been pressed the password must be insertedfor access to the  has been pressed the password must be inserted for access to the various  various menus. To access the user menu the password is 030. To  menus. To access the user menu the password is 000 (which is the de‐ modify the value of the password use thearrow keys. Once the correct  fault displayed); to modify the value of the password use the arrow keys.  password has been inserted, press the key shown in (Fig.A). The dis‐...
  • Page 10 (1)What type of system terminals are used in the heating circuit?  Reply  Operations to be performed      The unit is a cooling only model Go to question 2     Radiant panels (Floor, etc..) Set the parameter StC (index 3 USER menu) with the value of 35 C   Fan coils or low temperature radiators Set the parameter StC (index 3 USER menu) with the value of 45°C(default    value)     Other applications  Set the parameter StC (index 3 USER menu) with the value of 55 °C (2) Is the remote panel accessory installed (PR3) ?  Reply  Operations to be performed      Not installed Go to question 3   Installed Set the parameter PAN (index 9 INSTALLER menu) with the appropriate value,    selecting from:   Value (1):    • Season control piloted from the circuit board   • ON/OFF control enabled from PR3   Value (2):  ...
  • Page 11: Troubleshooting

    8. TROUBLESHOOTING           ANOMALY CAUSE SOLUTION       Check the presence of voltage   Check the safety systems upstream from  No electric voltage       the appliance   Master switch at OFF     Remote switch at OFF (if present)     Control panel at OFF   Position at ON   Main switch at OFF   The chiller does not start‐up   Compressor magnet circuit breaker at OFF     Power supply voltage too low Check power supply line  ...
  • Page 12 NON E' PERMESSO CONSEGNARE A TERZI O RIPRODURRE QUESTO DOCUMENTO PROGETTO: NE' UTILIZZARE IL CONTENUTO O RENDERLO COMUNQUE NOTO A TERZI SENZA LA NOSTRA NOME FILE: 4336825_00.sch AUTORIZZAZIONE ESPLICITA. OGNI INFRAZIONE COMPORTA IL RISARCIMENTO DEI DANNI TIPICO: Elettrico SUBITI. E' FATTA RISERVA DI TUTTI I DIRITTI DERIVANTI DA BREVETTI O MODELLI RCR1 RCR2 M5S1-1...
  • Page 13: Warranty

     The compressor is warranted for 5 years from the date of installation for residential application and 1 year for commercial applications. Aermec Fan Coil parts are warranted to be free from manufacturing defects up to 12 months from date of installation.
  • Page 14 The technical data given on the following documentation are not binding. Aermec reserves the right to apply at any time all the modifications deemed necessary for improving the product. 1608 Bonhill Road | Mississauga | ON | CA | L5T 1C7 Phone 905.564.2221...