152-388-115-03, Issue 03
Performance History at the HDSL2 Interface
The HDSL2 interface, shown in , has 31-day, 48-hour, 25-hour and current statistic screens for the H2TU-C.
Figure 15
shows an example of the 31-day history and
page 35
describes the error acronyms.
Monitor
Performance
------------------------------------------------------------------------------
Date
ES
04/09
04/10
04/11
04/12
04/13
04/14
04/15
04/16
04/17
04/18
04/19
04/20
04/21
14
------------------------------------------------------------------------------
Press <Space> to cycle through
choices and <Enter> to view
ID: xxxx--xxxx--xxxx--xxxx
Table 16. Error Acronyms Used on the HDSL2 Performance History Screens
H2TU-C-388 List 1E
Event Log
Config
H2TU-C HDSL2 31 Day History (Page 1 of 3)
SES
UAS
CV
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
10
14
10
Press: (N)ext Page, (P)revious Page, C(l)ear History
Interface
Statistics :
04/21/00 12:30:01
Figure 15. H2TU-C HDSL2 31-day Performance History
Error Acronym
Description
ES
Errored seconds
Seconds with HDSL2 CRC ≥1 or LOSW ≥1
SES
Severely errored seconds
Seconds with HDSL2 CRC ≥50 or LOSW ≥1
UAS
Unavailable seconds
Based on 10 contiguous SES occurrences
CV
Code Violation
Total count of HDSL2 CRC errors
LOSWS
Loss of Sync Word Second
Seconds with LOSW ≥1
Figure 16
shows a 25-hour history example.
Inventory
Rlogon
LOSWS
-
-
-
-
-
-
-
-
-
-
-
-
10
: H2TU-C HDSL2
31 Day History
H2TU-C
April 21, 2000
Monitoring System Activity and Performance
Table 16 on
Help
System: OK
35
Need help?
Do you have a question about the HiGain H2TU-C-388 List 1E and is the answer not in the manual?