152-388-115-03, Issue 03
O
VERVIEW
®
The ADC HiGain
product family is the industry's first practical implementations of High bit-rate Digital
Subscriber Line 2 (HDSL2). HiGain products are fully compliant with the HDSL2 standard. Providing full-rate
T1 access using just a single copper pair, HDSL2 is a cost-effective solution and offers an open architecture. The
open architecture inherent in HDSL2 guarantees interoperability, allowing simple, economic accommodation of
network growth.
HiGain HDSL2 products provide 1.552 Mbps transmission on one unconditioned copper pair over the full Carrier
Service Area (CSA) range. The CSA includes loops up to 12,000 feet of 24 American Wire Gauge (AWG) wire
or 9,000 feet of 26 AWG wire, including bridged taps.
F
EATURES
The H2TU-C-388 List 1E line unit is the Central Office (CO) side of a T1 transmission system.
•
HDSL2 transmission features
–
Lightning and power cross protection on HDSL2 interfaces
–
Full duplex HDSL2 transmission on one pair at 1.552 Mbps
–
Ultra-low wander (Stratum 1 compliant)
–
Grounded loop detection on High-bit-rate Digital Subscriber Line 2 (HDSL2)
•
Front-panel provisioning features
–
Four-character status display
–
Status LED
–
RS-232 craft port for connection to a maintenance terminal
•
HiGain HDSL2 maintenance screens for inventory, provisioning, and troubleshooting
–
High-performance, non-volatile performance monitoring
–
Non-volatile alarm histories
–
Performance Report Messaging (PRM) support for Supplemental PRM (SPRM) and Network PRM
(NPRM) at the H2TU-R
•
Configuration options
–
Selectable DS1 pre-equalizer
–
Bipolar Violation Transparency (BPVT) options
–
Bit Error Rate (BER) alarm
–
Loss of Signal/Alarm Indication Signal (LOS/AIS) payload alarm option
–
Remote provisioning
–
Selectable loopback activation codes
•
Compatible with Double Dual Module Plus (DDM+) high-density shelves
•
Flash download of firmware updates
•
Digital Data Service (DDS) latching loopback
•
Payload (PL) and HiGain (HG) loopback source identification
•
Network Management and Administration (NMA) interface