Provisioning
Table 6. H2TU-C-388 List 1E PairGain Config Screen Options
Front-panel
System Settings
Display
Screen Options
Code
Line Power Feed
PWRF
Remote Provisioning RTPV
Bipolar Violation
BPVT
Transparency
See
"Bipolar Violation Transparency
(BPVT) Option" on page
21.
HDSL2 BER
HBER
Threshold
See
"HDSL2 BER (HBER) Option"
on page
22.
DS1 BER
DBER
Special Loopback
SPLB
Mode
SmartJack Loopback LPBK
Minor Alarm
ALM
Network Alarm
NAIS
Indication Signal
H2TU-R DS1 Frame
CONV
Conversion
See
"H2TU-R DS1 Frame
Conversion (CONV) Option" on
page
22.
20
Selection
Description
OFF
Disables powering to the HDSL2 pair.
ON
Keeps the HDSL2 line voltage at nominal -185 Vdc.
ENA
Enables remote provisioning.
DIS
Disables remote provisioning.
ENA
Enables BPVs and HDSL2 CRC errors at the DS1 input to be converted into
DS1 BPVs at the DS1 output at the distant end.
This makes HiGain transparent to BPVs.
DIS
Disables BPV Transparency.
1E-6
The Status LED flashes red when the Block Error Rate (BER) exceeds 10
1E-7
The Status LED flashes red when BER exceeds 10
NONE
Prevents generation of a system alarm due to BER.
ENA
Enables the fixed 24-hour DS1 BER threshold.
DIS
Prevents the generation of a system alarm due to DS1 BER.
GNLB
Configures the HiGain system to respond to the generic inband loopback
codes.
A2LB
Configures the HiGain HDSL2 system to respond to the inband loopback
codes of the Teltrend addressable repeater.
A3LB
Configures the HiGain HDSL2 system to respond to the inband loopback
codes of the Wescom addressable repeater.
A4LB
Configures the HiGain HDSL2 system to respond to the inband loopback
codes of the Wescom Mod 1 addressable repeater.
ENA
Enables the HiGain HDSL2 system to recognize all inband SmartJack loopback
commands.
DIS
Configures the HiGain HDSL2 system to ignore all inband SmartJack loopback
commands.
ENA
Enables the generation of the output alarm on pin H when a system alarm
condition occurs.
DIS
Disables the generation of the output alarm on pin H when a system alarm
condition occurs.
CI
If ALMP is set to AIS, this option specifies which pattern is sent to the network
when a remote LOS or AIS occurs.
When configured for CI, an AIS-CI pattern is sent to the network.
AIS
When configured for AIS, an AIS pattern is sent to the network.
OFF
No frame conversion takes place at the H2TU-R. Framing is determined by the
FRMG option settings of AUTO and UNFR.
ACON
Auto detection of framing and potential frame conversion at the H2TU-R.
FCON
Auto detection of framing and forced frame format conversion at the H2TU-R.
April 21, 2000
152-388-115-03, Issue 03
-6
.
-7
.