152-388-115-03, Issue 03
Table 5
below describes the Standard Config screen options.
screen options. Selections in bold typeface are the factory default settings.
Table 5. H2TU-C-388 List 1E Standard Config Screen Options
Front-panel
System Settings
Display
Screen Options
Code
Loopback Timeout
LBTO
Loop Attenuation
LATT
Threshold
Margin Threshold
MARG
DS1 Frame
FRMG
Formatting
DS1 Line Coding
DS1
H2TU-C Equalization EQL
See
"H2TU-C Equalization (EQL)
Option." on page
21.
H2TU-R Line
RLBO
Buildout
Alarm Pattern
ALMP
H2TU-R TLOS
TLOS
Loopback
Network Loopback
NLBP
Pattern
H2TU-C-388 List 1E
Selection
Description
NONE
Disables automatic time-out cancellation of all loopbacks.
20
Sets automatic cancellation of all loopbacks to 20 minutes after initiation.
60
Sets automatic cancellation of all loopbacks to 60 minutes after initiation.
120
Sets automatic cancellation of all loopbacks to 120 minutes after initiation.
0 through
Determines the maximum loop attenuation before an alarm is declared.
40 dB
The loop attenuation threshold can only be set through the HiGain HDSL2
maintenance screens.
35 dB
Default value. Zero disables the alarm.
0 to 15 dB
Determines the minimum margin below which a system alarm can occur. Zero
disables the alarm.
The Margin Alarm Threshold can only be set through the HiGain HDSL2
maintenance screens.
4dB
Default value.
AUTO
Configures the HiGain HDSL2 system to operate in an auto-framing (AUTO)
mode. It detects and locks to both SF or ESF DS1 frame patterns.
Line and path performance parameters are maintained and displayed.
Unframed payloads will cause the ES-P and SES-P counters to increment.
UNFR
Same as the AUTO setting except unframed payloads will NOT cause the ES-P
and SES-P counters to increment.
B8ZS
Places both the H2TU-C and H2TU-R into their B8ZS modes.
AUTO
Places both the H2TU-C and H2TU-R into their AUTO framing modes.
AMI
Places both the H2TU-C and H2TU-R into their AMI modes.
0
Sets the Equalizer to DSX-1 for 0 to 133 feet.
133
Sets the Equalizer to DSX-1 for 133 to 266 feet.
266
Sets the Equalizer to DSX-1 for 266 to 399 feet.
399
Sets the Equalizer to DSX-1 for 399 to 533 feet.
533
Sets the Equalizer to DSX-1 for 533 to 655 feet.
0 dB
Sets the DS1 RLBO level toward the Customer Interface to 0 dB. H2TU-R Line
Buildout can only be set through the HDSL2 maintenance screens.
-7.5 dB
Sets the DS1 RLBO level toward the CI to -7.5 dB.
-15 dB
Sets the DS1 RLBO level toward the CI to -15 dB.
AIS
Enables the HiGain HDSL2 system to output an AIS payload at its DS1 ports
for LOSW and DS1 LOS.
See
Figure 23 on page 45
LOS
Enables the HiGain HDSL2 system to output an LOS condition at its DS1 ports
for LOSW and DS1 LOS.
ENA
Enables a logic loopback at the H2TU-R when an LOS occurs at its DS1 input,
if enabled at the H2TU-R.
See
Figure 23 on page 45
DIS
Disables TLOS logic loopback.
AIS
Enables the H2TU-R to transmit AIS toward the CI for any network loopback.
See
Figure 23 on page 45
LOS
Enables the H2TU-R to transmit LOS toward the CI for any network loopback.
April 21, 2000
Table 6 on page 20
describes the PairGain Config
for LOS/AIS response priorities.
for LOS/AIS response priorities.