ADC HiGain H2TU-C-388 List 1E User Manual page 31

Line unit
Hide thumbs Also See for HiGain H2TU-C-388 List 1E:
Table of Contents

Advertisement

152-388-115-03, Issue 03
If an ESF is received from the CPE, it is passed to the network, and the network's inbound framing is passed
on to the CPE.
FCON: This is the forced conversion setting.
ACON and FCON settings for the CONV option. The responses are identical, except in cases 3 and 4. In these
cases, the FCON reply is attempting to force the network or the far-end PM-NIU to send ESF. It also alerts
the CPE with an AIS alarm pattern while forcing the ESF to the network. Continuity is maintained as for
ACON.
Table 9
below and
Table 8. Response to H2TU-R DS1 Frame Conversion Options
Case
NET Transmit
1
ESF
2
ESF
3
SF
4
SF
ESF Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
H2TU-C-388 List 1E
Table 8
Table 10 on page 24
list the ESF and SF frame formats, respectively.
CPE Transmit
SF
ESF
ESF
SF
Table 9. Extended SuperFrame Format
Framing Pattern
Frame Bit for Datalink
Sequence (FPS) - 2 kb/s
0
0
1
0
1
1
April 21, 2000
below lists the HiGain HDSL2 responses to both the
ACON Option
FCON Option
NET > CPE
NET > CPE
NET < CPE
NET < CPE
ESF
SF
ESF
ESF ← SF
ESF ← SF
ESF
ESF
ESF
ESF ← ESF
ESF ← ESF
SF
SF
SF
ESF ← ESF
ESF ← ESF
SF
SF
SF
SF ← SF
ESF ← SF
Frame Bits
Cyclical Redundancy
(FDL) - 4 kb/s
Check (CRC) Bits - 2 kb/s
m
m
m
m
m
m
m
m
m
m
m
m
Provisioning
SF
ESF
AIS
AIS
C1
C2
C3
C4
C5
C6
23