Front Panel
Table 2
lists the front-panel display messages. The four-character display reports the code of an alarm, loopback,
or diagnostic message and, in some cases, is followed by a second four-character message that modifies the first
message with a value or current configuration setting.
Message
Full Name
ALARM MESSAGES
ACO
Alarm CutOff
ALRM
Alarm Condition Exists
DBER
DS1 Bit Error Rate
HBER
HDSL2 Block Error Rate
LA
Loop Attenuation
LAIS
Local Alarm Indication Signal
LLOS
Local Loss of Signal
LOSW
Loss of Sync Word
LRAI
Line Remote Alarm Indication Signal
MAL
Margin Alarm
PRMF
Performance Report Messaging - Far
End
PRMN
Performance Report Messaging - Near
End
PWR FEED GND
Ground
PWR FEED OPEN
Open
PWR FEED SHORT
Short
RAIS
Remote Alarm Indication Signal
RLOS
Remote Loss of Signal
RRAI
Remote RAI
TRCI
TX RAI-CI Indication - Customer
Installation
TUC
Transmission Unit Central Office
TUR
Transmission Unit Remote End
LOOPBACK MESSAGES
CLOC
Customer Local Loopback
CREM
Customer Remote Loopback
NLOC
Network Local Loopback
6
Table 2. Front-panel Display Messages
Description
A system alarm has occurred and has been retired to an ACO
condition once the SEL button on the H2TU-C front panel is pressed.
A system alarm condition is in effect.
A system DS1 BER alarm is in effect and remains in effect until cleared.
A system HDSL2 Block Error Rate alarm is in effect.
Indicates that the attenuation on the HDSL2 loop has exceeded the
maximum threshold value.
Indicates an AIS (all ones) pattern is being transmitted from the
local DS1 output port.
Indicates that no signal is detected at the DSX-1 input to the
H2TU-C. Causes a system alarm.
Indicates that the HDSL2 loop has lost synchronization.
Indicates an RAI alarm (yellow) from the CPE with an error-free
signal from the line unit or network.
The margin on HDSL2 loop has dropped below the threshold
(0 to 15 dB) as set by the operator.
H2TU-R PRM-FE BER threshold has been exceeded.
H2TU-R PRM-NE BER threshold has been exceeded.
The HDSL2 loop is grounded.
Indicates a line power open condition.
Indicates a short between the Tip and Ring of the HDSL2 pair.
Indicates an AIS (all ones) pattern is being received at the H2TU-R
DS1 input port.
Indicates that no signal is detected at the DS1 input to the H2TU-R.
Causes a system alarm.
Remote Alarm Indication at the H2TU-R - Indicates an RAI alarm
(yellow) from the CPE with errors from the line unit or network.
Upon reception of an RAI (yellow alarm) from the CPE, the H2TU-R
sends RAI-CI toward the network, if the network signal received at the
H2TU-R is clear.
If the network signal is impaired (LOS, AIS or Loss of Frame [LOF]),
then the RAI is automatically passed to the network.
Accompanies the HBER, MAL, and LA alarms and indicates that the
alarm has occurred at the H2TU-C central office unit.
Accompanies the HBER, MAL, and LA alarms and indicates that the
alarm has occurred at the H2TU-R remote unit.
Signal from customer is looped back to the customer at the H2TU-R.
Signal from customer is looped back to the customer at the H2TU-C.
DSX-1 signal is looped back to the network at the H2TU-C.
April 21, 2000
152-388-115-03, Issue 03
Continued
H2TU-C-388 List 1E