Update Fixture Firmware Using the USB Port
Navigate: Main Menu → Set → USB Update
Fixture firmware updates are available on the ETC website at
End-Systems.
1. Save the firmware update file to a USB drive.
2. Insert the USB drive into the USB port on the fixture base.
3. On the Main Menu, select Set → USB Update. The fixture reads the USB drive and displays
a list of any firmware update files on the USB drive.
4. Select the appropriate file and then press the Enter button.
5. The software prompts you to confirm the update with the message "Update fixture?" Use
the navigation buttons to select "Yes," and then press the Enter button to start the
firmware update.
A progress monitor shows you the progress of the update.
When the update is complete, the fixture performs a data check to verify the update and
then the fixture restarts itself.
The firmware update is complete when the display returns to its default state.
6. Remove the USB drive from the fixture.
Reset Fixture to Factory Default Settings
Navigate: Main Menu → Set → Reset Default
Select ON to reset the fixture to the factory default settings.

Test Menu

Reset (Home) the Mechanical Positions on the Fixture
Navigate: Main Menu → Test → Home
Reset ("home") all features on the fixture, including, pan, tilt, colors, gobos, etc.
Test the Fixture
Navigate: Main Menu → Test → Self Test
Run a self-test program on the fixture. When you run the test, the display indicates "Running"
and the fixture automatically runs a self-test procedure, testing each of the functions. Press
the [MODE/ESC] button to end the self-test and return the display to the previous menu.
Test an Individual Channel
Navigate: Main Menu → Test → Test Channel
Run a self-test program on individual channels. The default value is Control. Select a different
channel to run a self-test on that channel.
Manually Set an Individual Channel
Navigate: Main Menu → Test → Manual Ctrl.
Select an individual channel on the fixture and manually set the channel value. While in
Manual Control mode, all effects are canceled, the shutter opens, and the dimmer intensity is
set to 100%.