INSTALLATION

HDW-1R2 MODEL

Care should be taken when unpacking shipping carton
to avoid damage to unit and components enclosed.
1. Remove the unit from the carton.
2. Remove plastic bag containing four adjustable legs
from inside the drawer.
CAUTION
The National Sanitation Foundation (NSF) requires
that HDW-1R2 Series units over 36" (91 cm) in
length or weighing more than 80 lbs. (36 kg) to be
either sealed or raised on the installation surface.
If this unit cannot be sealed at the point of use,
4" (10 cm) legs are included to allow for proper
cleaning access below unit. See INSTALLATION
instructions for details.
3. Carefully lay unit on its side (requires 2 people).
Install legs to bottom of unit as shown in Figure 3.
Hand tighten legs until snug. Do not overtighten.
CAUTION
Do not lay unit on the front or back side or damage
to unit could occur.
4. Return unit to the upright position.
5. Remove all tape from the unit.
NOTE: Legs are adjustable for leveling the unit. Use
a 9/16" (14 mm) open-end wrench to make leveling
adjustments once the unit is placed in final position.
Form No. HDW1R2M-0502
Leg Adjustment
Adjust leg using a 9/16"
(14 mm) open-end wrench
and turning bottom of leg
accordingly.
Figure 3. Adjustable Legs

LOCATION

Locate the unit at the proper counter height, in an
area that is convenient for use. The location should
be level to prevent the unit or its contents from
accidentally falling, and strong enough to support
the weight of the unit and food.
For safe and proper operation, the unit must be
located a reasonable distance from combustible walls
and materials. If safe distances are not maintained,
discoloration or combustion could occur.
4
Leg Installation
CAUTION