Quell Q2300 User Manual page 8

240v mains photoelectric long life smoke alarm 240v ac, 50hz, 15ma max, 9v back up, standalone or interconnected 24 units maximum
Table of Contents

Advertisement

Recommended Locations for Alarms
• When mounting the alarm on a sloping ceiling, it should not exceed
1500mm away from the apex. The spacing of additional alarms, if
any, should be based on a horizontal distance measurement, not a
measurement along the slope of the ceiling (see Figure 2B )
ANYWHERE IN THIS
• In rooms with open joists or beams,all ceiling mounted alarms shall be
located on the bottom of such beams. (See Figure 2C )
• Alarms installed on an open-joist ceiling shall have the smooth ceiling
spacing reduced to no more than half of the listed spacing when
measured at right angles to the solid joist. (See Figure 2C)
1000 mm
AREA
SLOPED CEILING
500 mm
NOT IN
THIS AREA
DEAD AIR
DO NOT INSTALL
2B
Figure
The alarm should be
located between 500
mm snf 1500 mm of
the highest point.
Figure 2C
6

Hide quick links:

Advertisement

Table of Contents