6
Studio One Profesional Quick Start
6.6
Pipeline XT
1. Send Output. This dropdown menu allows you to select the physical
Quantum 4848 output you would like to use to connect to your
external hardware unit. Note: Mono instances of Pipeline XT require a
mono output bus. Stereo instances of Pipeline XT can use mono or
stereo output buses.
2. Send Meter. Monitors the output level from Studio One to your
external hardware unit.
3. Send Level. Adjusts the send level from Studio One to your external
hardware unit.
4. Text Edit. Click to add notes about your Pipelinesetup.
Notes will appear in the field to the right.
5. Show Picture.Pipeline XT supports adding a picture of your hardware
unit. This can be especially useful to store setting to recall later. When
viewing the image, clicking on the "..." in the upper right corner will
allow you to add a new image. Image size is limited to 1200x1200 pixels.
6. Scope Mode.Provides a visualization of the live input and output signals.
While in this mode, you'll be able to hear both the input and the output
signals simultaneously. This will allow you to check for phasing issues and
adjust the offset if necessary. Scope Mode is mutually exclusive with Setup
Mode (#19).
7. Sensitivity Control.Use this control to adjust how the scope reacts to
transients. As you move the slider to the right, the sensitivity is
lowered.
8. Difference. Displays the difference between the send and return signals.
If the latency is compensated correctly and both signals are gain staged
the same, the curves will be aligned and the difference signal will be zero.
9. Zoom. Click to Zoom in on the Scope measurement.
10. Mix. Pipeline lets you blend the pre processed signal with the
processed signal. Use the Mix control to set the blend.
11. Phase Invert. Flipsthe polarity of the return signal.
12. Return Level. Sets the level of the returnsignalto Studio One.
13. Scope / Image display. This field will display the scope result or a
custom image depending on the mode.
14. Return Meter. Displays the return level from your external hardware
unit to Studio One.
15. Return Input.This dropdown menu allows you to select the physical
input on your Quantum 4848 to which the return signal from your
external hardware is connected. Note: Mono instances of Pipeline XT
require a mono input. Stereo instances of Pipeline XT require a stereo
input.
16. Manual Offset. Use these controls to manually adjust the offset to
compensate for latency.
17. Name. Click to add the name of the hardware to which Pipeline XT is connected.
18. Auto.Click the Auto button after wiring and configuring your
Quantum 4848