Manitowoc SM050 Technician's Handbook page 97

Undercounter ice machines
Table of Contents

Advertisement

Cube Weight Adjustment
The cube weight can be increased from the factory
setting by adjusting the finish time.
ADDITIONAL FINISHING TIME CHECK
1. Press and hold the power button for 5 seconds.
2. Count the flashes on the Automatic Ice Making
light. The light will flash once for each additional
minute of freeze cycle time.
ADJUSTING FINISHING TIME
Adjust in 1 minute increments and allow the ice
machine to run several freeze/harvest cycles, then
inspect the ice cubes. If a heavier cube weight is
desired add another minute of freeze time and repeat
the process.
1. Press and hold the "Power" button.
2. Press and release the "Clean" button once for
each additional minute of freeze cycle time
desired.
3. Five minutes is the maximum additional freeze
time that can be added. Pressing the clean button
6 times will reset the finishing time to zero
additional minutes.
POWER
Part Number 8001119 10/19
DELAY
START
AUTOMATIC
ICE
MAKING
SM050 Control Panel
SM050 Ice Cube
CLEAN
2
4
8
HOURS
REPLACE
WATER FILTER
TO RESET:
PUSH AND HOLD CLEAN
BUTTON FOR 6 SECONDS
97