Sm50; Cleaning Procedure - Manitowoc SM050 Technician's Handbook

Undercounter ice machines
Table of Contents

Advertisement

SM50

CLEANING PROCEDURE

SM50 uses a tin plated evaporator. Do not use
standard cleaner, use only 000000084 cleaner for this
ice machine.
Use only Manitowoc approved Ice Machine
Cleaner (part number 000000084 clear metal safe
ice machine cleaner) and Sanitizer (part number
94-0565-3). It is a violation of Federal law to use
these solutions in a manner inconsistent with their
labeling. Read and understand all labels printed
on bottles before use.
Ice machine cleaner is used to remove lime scale or
other mineral deposits. It is not used to remove algae
or slime. Refer to "Sanitizing Procedure" on page 68
for removal of algae and slime.
1. To start a cleaning cycle, press the CLEAN
switch. The ice machine will initiate a 2 minute
harvest to remove any ice from the evaporator.
Or, set the switch to the OFF position and allow
the ice to melt off the evaporator.
Never use anything to force ice from the
evaporator. Damage may result.
2. Remove all ice from the bin.
3. The clean light will energize to indicate the clean
cycle has started.
4. Wait until the Clean light flashes (3 minutes) then
add 3 oz of Manitowoc cleaner by lifting the water
shutter and pouring directly into the spray area.
The ice machine will automatically time out a ten
minute cleaning cycle, followed by eight rinse
cycles, and stop. The Clean light will turn off to
indicate the Clean cycle is complete. This entire
cycle lasts approximately 30 minutes.
Part Number 8001119 10/19