Qm45 Operating Temperatures - Manitowoc SM050 Technician's Handbook

Undercounter ice machines
Table of Contents

Advertisement

QM45 OPERATING TEMPERATURES

NOTE: Suction temp drops gradually throughout the freeze cycle.
50°F (10°C) Water
Air Temp.
Entering
Condenser
50°F
(10°C)
70°F
(21°C)
80°F
(27°C)
90°F
(32°C)
100°F
(39°C)
70°F (21°C) Water
Air Temp.
Entering
Condenser
50°F
(10°C)
70°F
(21°C)
80°F
(27°C)
90°F
(32°C)
100°F
(39°C)
90°F (32°C) Water
Air Temp.
Entering
Condenser
50°F
(10°C)
70°F
(21.1°C)
80°F
(26.7°C)
90°F
(32.2°C)
100°F
(38.8°C)
Part Number 8001119 10/19
Freeze Cycle
Discharge
Temp
°F (°C)
150-165
(66-74)
155-185
(68-85)
170-190
(78-88)
180-205
(82-96)
190-215
(88-102)
Freeze Cycle
Discharge
Temp
°F (°C)
155-175
(68-79)
160-185
(71-85)
170-200
(77-93)
180-205
(82-96)
190-220
(88-104)
Freeze Cycle
Discharge
Temp
°F (°C)
155-180
(68-82)
160-185
(71-85)
170-195
(77-91)
190-205
(88-96)
190-215
(88-102)
Suction
Discharge
Temp
Temp
°F (°C)
°F (°C)
67-50
155-190
(19-10)
(68-88)
67-50
160-190
(19-10)
(71-88)
71-58
175-190
(22-14)
(79-88)
75-65
185-210
(24-18)
(85-99)
85-70
195-220
(29-21)
(91-104)
Suction
Discharge
Temp
Temp
°F (°C)
°F (°C)
68-58
160-175
(20-14)
(71-79)
70-50
160-190
(21-10)
(71-85)
75-58
170-200
(24-14)
(77-94)
85-65
185-210
(29-18)
(85-99)
88-70
200-220
(31-21)
(93-104)
Suction
Discharge
Temp
Temp
°F (°C)
°F (°C)
75-50
160-185
(24-10)
(71-85)
75-53
165-190
(24-12)
(74-88)
80-58
175-195
(27-14)
(79-91)
85-64
195-215
(29-18)
(91-102)
91-70
195-220
(33-21)
(91-104)
Harvest Cycle
Suction
Temp
°F (°C)
50-60
(10-16)
50-60
(10-16)
52-65
(11-18)
55-70
(13-21)
60-75
(16-24)
Harvest Cycle
Suction
Temp
°F (°C)
50-60
(10-16)
50-65
(10-18)
55-70
(13-21)
55-75
(13-24)
60-75
(16-24)
Harvest Cycle
Suction
Temp
°F (°C)
52-65
(11-18)
52-65
(11-18)
57-75
(14-24)
55-75
(13-24)
60-80
(16-27)
207

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qm30Qm45Qm20Q130Q170Q210 ... Show all

Table of Contents