Toshiba ESTIA R32 HWT-401HW-E Manual page 59

Air-to water heat pump
Table of Contents

Advertisement

Output 1 options:
0 = Alarm output
1 = Compressor operating output
2 = Defrost operating output
3 = Boiler control output
4 = Safety or protection control running
5 = Backup heater ON
6 = Hot water tank heating ON
7 = Heating mode ON
8 = Cooling mode ON
9 = Hot water preparation mode ON
Output 2 options:
0 = Alarm output
1 = Compressor operating output
2 = Defrost operating output
3 = Boiler control output
4 = Safety or protection control running
5 = Backup heater ON
6 = Hot water tank heating ON
7 = Heating mode ON
8 = Cooling mode ON
9 = Hot water preparation mode ON
Hydrobox digital outputs
Output 3 options:
0 = Alarm output
1 = Compressor operating output
2 = Defrost operating output
3 = Boiler control output
4 = Safety or protection control running
5 = Backup heater ON
6 = Hot water tank heating ON
7 = Heating mode ON
8 = Cooling mode ON
9 = Hot water preparation mode ON
Output 4 options:
0 = Alarm output
1 = Compressor operating output
2 = Defrost operating output
3 = Boiler control output
4 = Safety or protection control running
5 = Backup heater ON
6 = Hot water tank heating ON
7 = Heating mode ON
8 = Cooling mode ON
9 = Hot water preparation mode ON
ESTIA control type:
0 = Normal control
1 = Target temperature control (DN 681~DN 684)
2 = Direct capacity control - HTG/CLG mode
(AI1)
3 = Direct capacity control - hot water
(AI 2)
4 = Direct capacity control - HTG/CLG (AI 1)
& hot water (AI 2)
Hot water set temperature - selection of analog
input (AI)
0 = Analog input not used
1 = AI 1 2 = AI 2 3 = AI 3
Zone 1 set temperature (HTG) - selection of analog
input
0 = Analog input not used
1 = AI 1 2 = AI 2 3 = AI 3
Zone 2 set temperature (HTG) - selection of analog
0-10 V interface
input
(optional)
0 = Analog input not used
1 = AI 1 2 = AI 2 3 = AI 3
Zone 1 set temperature (CLG) - selection of analog
input
0 = Analog input not used
1 = AI 1 2 = AI 2 3 = AI 3
Upper limit of hot water set temperature
Accuracy of hot water set temperature
Upper limit of Zone 1 set temperature (HTG)
Accuracy of Zone 1 set temperature (HTG)
Upper limit of Zone 2 set temperature (HTG)
Accuracy of Zone 2 set temperature (HTG)
Upper limit of Zone 1 set temperature (CLG)
Accuracy of Zone 1 set temperature (CLG)
Storage location
Function code
FC description
HB*
6CA
6CC
6CD
6CB
680
681
682
683
684
685
689
686
68A
687
68B
688
68C
no .
RC*
Range
Preset
-
0~9
-
0~9
-
0~9
-
0~9
-
0~4
-
0~3
-
0~3
-
0~3
-
0~3
-
40~80
65
-
1~5
-
20~55 (65)
55
-
1~5
-
20~55 (65)
55
-
1~5
-
7~29
20
-
1~5
*HB= Hydrobox EEPROM
*RC= Remote Control
Additional info
0
2
3
1
0
0
0
0
0
5
3
3
1
TOSHIBA I 19