FC description
User-defined options for I/P7 /8 (SN21):
0: I/P 7 = Forced stop input; I/P 8 = None
1: I/P 7 = TEMPO 1 input; I/P 8 = None
System setup
2: I/P 7 = TEMPO 2 input; I/P 8 = None
(DPSW replacement)
3: I/P 7 = Forcefully switch off reserve heating
I/P 8 = Switch off hot water externally
4: I/P 7 = SMART Grid network input 1
I/P 8 = SMART Grid network input 2
Hydrobox type setting:
Hydrobox type setting
70 = Wall-mounted Hydrobox
71 = ALL-IN-ONE Hydrobox
Capacity of the water-to-air heat exchanger:
Hydrobox capacity
0010 = 401 / 601
setting
0015 = 801 / 1101
Outdoor unit type setting
0 = 401 / 601
Outdoor unit type setting
1 = 801 / 1101
2, 3 = None
Refrigeration cycle address
Indoor unit address
Group address
Addressing
0= Individual (no group control)
1= Master unit
2= Slave unit
Central address
The temperature increase in "Forced ON" mode
(SG Ready control)
SG Ready
SG Ready forced operation heating control
0 = Heating capacity permitted
1 = Heating capacity not permitted
Current consumption function used
Energy consumption
0 = OFF
1 = ON
Storage location
Function code
no .
HB*
RC*
Range
-
B6
0~4
10
-
70 or 71
11
-
0010 or 0015
6BD
-
0~3
-
12
1~128
-
13
1~128
14
-
0~2
03
-
1~128
AC
-
0~10
6CE
-
0~1
-
1B
0~1
*HB= Hydrobox EEPROM
*RC= Remote Control
Preset
Additional info
0
Depending on
Hydrobox
Depending on
Hydrobox
Depending on
type
None
None
None
None
Used if ESTIA is controlled via a central controller.
0
0
1
TOSHIBA I 9
I 9
TOSHIBA