Toshiba MMY-MUP0801HT8P-E Owner's Manual

Toshiba MMY-MUP0801HT8P-E Owner's Manual

Air conditioner multi type r410a for commercial use, outdoor unit
Hide thumbs Also See for MMY-MUP0801HT8P-E:

Advertisement

AIR CONDITIONER (MULTI TYPE)
Owner's Manual
Outdoor Unit
Model name:
<Heat Pump Model>
MMY-MUP0801HT8P-E
MMY-MUP1001HT8P-E
MMY-MUP1201HT8P-E
MMY-MUP1401HT8P-E
MMY-MUP1601HT8P-E
MMY-MUP0801HT8JP-E
MMY-MUP1001HT8JP-E
MMY-MUP1201HT8JP-E
MMY-MUP1401HT8JP-E
MMY-MUP1601HT8JP-E
MMY-MUP1801HT8P-E
MMY-MUP2001HT8P-E
MMY-MUP2201HT8P-E
MMY-MUP2401HT8P-E
MMY-MUP1801HT8JP-E
MMY-MUP2001HT8JP-E
MMY-MUP2201HT8JP-E
MMY-MUP2401HT8JP-E
R410A
For commercial use
English

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba MMY-MUP0801HT8P-E

  • Page 1 AIR CONDITIONER (MULTI TYPE) Owner’s Manual R410A For commercial use Outdoor Unit Model name: <Heat Pump Model> MMY-MUP0801HT8P-E MMY-MUP1801HT8P-E MMY-MUP1001HT8P-E MMY-MUP2001HT8P-E MMY-MUP1201HT8P-E MMY-MUP2201HT8P-E MMY-MUP1401HT8P-E MMY-MUP2401HT8P-E MMY-MUP1601HT8P-E MMY-MUP0801HT8JP-E MMY-MUP1801HT8JP-E MMY-MUP1001HT8JP-E MMY-MUP2001HT8JP-E MMY-MUP1201HT8JP-E MMY-MUP2201HT8JP-E MMY-MUP1401HT8JP-E MMY-MUP2401HT8JP-E MMY-MUP1601HT8JP-E English...
  • Page 2: Table Of Contents

    Toshiba Carrier Corporation or, alternatively, he or she has Children shall not play with the appliance. Cleaning and user been instructed in such matters by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work.
  • Page 3 Definition of protective gear Warning indications on the air conditioner unit When the air conditioner is to be transported, installed, maintained, repaired or removed, wear protective gloves and ‘safety’ work clothing. Warning indication Description In addition to such normal protective gear, wear the protective gear described below when undertaking the special work detailed in the table below.
  • Page 4: Precautions For Safety

    – 3 – Installation Precautions for safety • Only a qualified installer(*1) or qualified service person(*1) is allowed to carry out the electrical work of the air conditioner. Under no The manufacturer shall not assume any liability for the damage circumstances must this work be done by an unqualified individual caused by not observing the description of this manual.
  • Page 5 • Do not move or repair any unit by yourself. Since there is high voltage Repairs inside the unit, you may get electric shock when removing the cover • When you have noticed that some kind of error (such as when an and main unit.
  • Page 6 – 5 – • Do not put a water container such as a vase on the unit. Water CAUTION intrusion into the unit may occur and it may cause deterioration of electric insulation and result in electric shock. To disconnect the appliance from the main supply •...
  • Page 7: Part Names

    ■ Connectable indoor units Part names Model type Model Name ■ Outdoor unit 4-Way Cassette MMU-UP✱✱✱✱H✱ Compact 4-Way Cassette MMU-UP✱✱✱✱MH✱ Air discharge 2-Way Cassette MMU-UP✱✱✱✱WH✱ Warm air comes out when cooling, MMU-UP✱✱✱✱YHP✱ and cool air when heating. 1-Way Cassette MMU-UP✱✱✱✱SH✱ NFC tag Concealed Duct, Standard MMD-UP✱✱✱✱BH✱...
  • Page 8 – 7 – Compact 4-Way cassette Type 1-way Cassette Type MMU-UP✱✱✱✱MH✱ MMU-UP✱✱✱✱YHP✱ Hook Discharge louver Open / close the return air grille. Controls discharge air directions. Air intake grille Air in the room is taken in Earth screw through here. Equipped on the electrical control box.
  • Page 9 Concealed Duct High Static Pressure Type Floor Standing Cabinet Type MMD-UP018✱H✱ - MMU-UP048✱H✱ MML-UP✱✱✱✱H✱ Air discharge Connect a discharge duct. Discharge louver Controls discharge air directions. Electrical control box Air filter The earth screw is provided in the Filters out dust. electrical control box.
  • Page 10: Part Names And Functions Of The Remote Controller

    – 9 – ■ Indicators Part names and functions of the remote All icons on the display are shown for this explanation. Operations are not accepted when “SETTING” is controller flashing. Remote controller model name : RBC-ASCU11-E LCD backlight lights for 15 seconds during remote controller operation. All indicators are displayed in the display example below.
  • Page 11: Operation

    Operation OFF timer operation When you use the air conditioner for the first time or change the settings, follow the procedures below. From next OFF timer : The indoor unit stops when the set time is reached. time, pushing the ON/OFF button starts running of the air conditioner with the chosen settings. ■...
  • Page 12: Louver Direction

    – 11 – ■ ■ 4-way cassette type 1-way cassette type Louver direction (SH series) When cooling Point the louver horizontally. When cooling For cooling NOTE Point the louver horizontally to send cool air across the The louver can be adjusted to four steps. To improve the cooling / heating performance, change entire room.
  • Page 13 ■ ■ Under ceiling type Floor standing type How to change the louver angle Vertical adjustment Vertical adjustment ⑧ ⑦ When cooling When cooling ⑥ ⑤ Point the louver horizontally to send cool air across the Move the louver manually and point it horizontally to ④...
  • Page 14: Installation

    – 13 – ■ Floor standing cabinet type Changing the air discharge Installation Follow the procedure below to change the air When cooling discharge: Move the louver manually and point it horizontally to ■ Location send cool air across the entire room. Remove the two fixing screws of the air •...
  • Page 15: Notes On Operations And Performance

    ■ Cooling / Heating operations Notes on operations and performance Each unit can be controlled individually. However, indoor units connected to the same outdoor unit cannot perform ■ cooling and heating simultaneously. ■ Check before operation Protective device When you attempt simultaneous operation, indoor units performing cooling are stopped, and the running (High pressure switch) preparation indicator is displayed on the remote controller.
  • Page 16: Tips For Energy Saving And Comfortable Performance

    – 15 – Tips for energy saving and comfortable Maintenance performance WARNING To save energy and perform comfortable cooling and heating For daily maintenance including Air Filter cleaning, make sure to ask the qualified service person Clean the air filter often Do not cool / heat too much particularly following models;...
  • Page 17 ■ ■ Cleaning the indoor unit and Before the cooling season Floor standing cabinet type Floor standing concealed type remote controller Ask a qualified service person to clean the drain Push down the upper part of the air intake Push down hook of the air filter on the front grille slightly, and then pull it toward you to panel (Lower side).
  • Page 18: When The Following Symptoms Are Found

    – 17 – ■ Confi rmation and check When the following symptoms are found If a problem occurs with the air Check the points described below before asking repair servicing. conditioner, the OFF timer indicator alternately shows the check code Symptom Cause and the indoor Unit No.
  • Page 19: Specifi Cations

    Declaration of Conformity Specifi cations Manufacturer: Toshiba Carrier (Thailand) Co., Ltd. Sound power level (dBA) Model Weight (kg) 144 / 9 Moo 5, Bangkadi Industrial Park, Tivanon Road, Tambol Bangkadi, Cooling Heating Amphur Muang, Pathumthani 12000, Thailand MMY-MUP0801HT8P-E MMY-MUP0801HT8JP-E TCF holder: TOSHIBA CARRIER EUROPE S.A.S...
  • Page 20 1141002201...