ESTIA R32 refrigerant piping
New Hydrobox hanging on the wall
ESTIA R32:
Basic refrigerant charge:
401/601 = 0.9 kg
801/1101 = 1.25 kg
ESTIA series 5:
Max. height = 10 m
Max. length = 15 m
Max. height H
Outdoor unit
HWT-401/601HW-E
HWT-801/1101H(R)W-E
The ESTIA must be installed by qualified engineers in compliance with all local and national regulations
Outdoor unit
Max. length L (m)
(m)
±30
30
±30
30
ESTIA R32:
Additional refrigerant charge
401/601 = 20 g/m
801/1101 = 25 g/m
Min. length (m)
Max. unfilled (m)
5
20
5
8
ESTIA series 5:
Liquid pipe Ø = 9.58 mm
Liquid
Gas line (Ømm)
pipe (Ømm)
12.70
6.35
6.35
15.88