Details Of Flags - Omron CK3E Series Hardware User Manual

Programmable multi-axis controller
Hide thumbs Also See for CK3E Series:
Table of Contents

Advertisement

5-4-2

Details of Flags

 FlashSizeErr
Register name
Description
Range
Details
Detection timing
Recovery
Effects
Cause and cor-
rection
Precautions/
Remarks
 BufSizeErr
Register name
Description
Range
Details
Detection timing
Recovery
Effects
Cause and cor-
rection
Precautions/
Remarks
 AbortAll
Register name
Description
Range
Details
Detection timing
Recovery
Effects
Cause and cor-
rection
Precautions/
Remarks
CK3E-series Programmable Multi-Axis Controller User's Manual Hardware (I610)
Sys.FlashSizeErr
The user program size exceeds the built-in flash memory capacity.
0 to 1
0: No error
1: The user program size exceeds the built-in flash memory capacity.
When save command is issued
Re-issue save command.
Save command is invalidated.
Cause (Assumed cause)
The user program size is
too large.
None
Sys.BufSizeErr
The buffer size set in the user program exceeds the built-in RAM capacity.
0 to 1
0: No error
1: Buffer size exceeds the built-in RAM capacity.
When power is turned ON or the Controller is reset.
Cycle the power supply, or issue reset command ($$$)
The buffer size is changed to the default value.
Cause (Assumed cause)
The buffer size set in the
user program is too large.
None
Sys.AbortAll
Stop by Abort all input
0 to 1
0: No stop by Abort all input
1: Stopped by Abort all input, or stopped in the past by Abort all input.
With Abort all input
Cycle the power supply, or issue reset command ($$$)
Operation continues
Cause (Assumed cause)
Abort all was input.
None
Correction
Reduce the size of the user
program.
Or, delete the backup file.
Correction
Reduce the buffer size.
Correction
None
5 Error Processing
Prevention
None
Prevention
None
Prevention
None
5-9