5 Error Processing
Error occurs.
PWR/ERR
Lit in red.
indicator (green/red)
RDY indicator
ECAT LINK
Indicator (orange)
Ethernet LINK
Indicator (orange)
*1. For the details of errors that cannot be determined solely by checking the indicators, check the Sys.status reg-
ister.
Refer to 5-4-1 Sys.Status Register List on page 5-8 for the Sys.status flag.
5-4
Not lit.
Lit in green.
Not lit.
(green)
Connectable?
Lit.
Not lit.
Lit.
Not lit.
Lit.
CK3E-series Programmable Multi-Axis Controller User's Manual Hardware (I610)
Power
NO
PMAC IDE
YES
Fatal errors in the Motion
Controller
Power supply error
Watchdog timer error
Initial process error
Non-fatal errors in the Motion
Controller
The EtherCAT physical layer link
is not established.
The Ethernet physical layer link
is not established.
Interrupted communications
between Power PMAC IDE and
Motion Controller
EtherNet/IP connection is not
established.
The Ethernet physical layer link
*1