Function Instruction
5.Water supply: the sign shows that water is supplying.
6.Pressure sign: the sign shows that pump is working.
7.Water level : display water level with four grids.
8.Water temperature display: generally it shows the actual water temperature,
when the number is flickering, it displays the set temperature of electric heating,
and getting the set value, electric heating will automatically stop.
9.Electric heating sign: the sign shows the electric heater is working.

Main function

1.Display function: display water temperature, water level, clock, various
running symbols etc.
2.Manual water supply: press
key , and then act immediately.
3.Time water supply: water tank capacity is divided into four level. The water
level and water supply time can be pre-set as per need, water will be supplied to
pre-set level at pre-set time automatically.
4.Manual heating: press
, key electric heating can be activated
immediately, when the water temperature reaches the setting value, electric
heating will be shut down automatically.
Note: the set temperature range of controller is 30
80
5.Pre-set heating: start-up time of electric heating can be set arbitrarily (advise
setting between 15:00 and 17:00). If the water temperature reaches the pre-set
temperature before pre-set time, the electric heating will cancel automatically. If
the water temperature doesn't reach the pre-set temperature within pre-set time,
electric heating will activate automatically, electric heating will be shut down
automatically, when the water temperature reaches the pre-set temperature.
6.Automatic water supply: when controller shows no water for 15 minutes, the
system will open electromagnetic valve to supply water automatically.
7.System resume: when blackout, the battery built-in the controller will backup
the pre-set information, when electrified again, the controller can run according
to the pre-set mode.
8.Error display: error code will display on the screen..
9.Forced water supply: when the sensor has fault, water can be supplied by
pressing
key .Buzzer sounds once per minute, water supply will stop in
eight minutes.