Veratron VL FLEX 52MM Series User Manual page 14

Table of Contents

Advertisement

Available languages

Available languages

7. CALIBRATE THE SENSOR
The VL Flex assumes the data is received from the J1939
network as a default. This means the analog inputs are usually
disabled.
If there is an actual sensor connected to one of the gauges
analog inputs (frequency, resistive or IBS-input), it can be
calibrated in the register "Input" after activating the input
with the switches on the right side.
Note: Depending on the chosen data type, you can either
activate the resistive input, the frequency input, the IBS-
Input or for some values even no sensor input at all. (See table
"Supported Configurations")
If there are two data types selected for the dual layout, which
can be measured over the same type of analog input, then
you must choose here, which of the two values is connected
to the input and which value is received over J1939. (There is
always just one analog input of a kind.)
8. SET ILLUMINATION BRIGHTNESS AND CLOCK
The last few configurations can be found in the register
"settings".
In this section you can set the display brightness for the day-
and night mode by moving the sliders.
Here you can also manage the clock setting.
Note: The clock can only receive the time over the J1939
interface (and only if there is some kind of clock connected to
your network). There is no way, the VL Flex can internally
maintain the time.
9. WRITE THE CONFIGURATIONS ONTO THE VL FLEX
After you finished choosing your settings, you can load the
configurations onto the VL Flex device.
Hit the button "APPLY" in the upper right corner and touch
the front lens of the gauge one more time with the backside
of your smartphone to transfer the data.
CONFIGURATION
B001026

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Vl flex 52 j1939B00086001B00110901

Table of Contents