Error Message
C202
The error occurred during
CPU configuration check.
C203
CPU Configuration change is
detected.
C300
Out-of-band setup
configuration failure
C301
SDR mismatch error.
Hardware configuration error.
C302
Hardware configuration of
C310
cooling is insufficient.
Unmatched PSUs.
C320
System power consumption is
C321
out-of-range in PSUs.
No information for system
C322
power consumption check.
ME is in Recovery Mode.
C501
112
Cause
The CPU information could not be
obtained.
The CPU configuration has
changed since the previous startup.
Configuration change requested by
remote terminal via network failed.
Inconsistency in the hardware
information of the sensor data record
was detected
Illegal hardware configuration was
detected.
Detected that cooling power is
insufficient in this hardware
configuration.
Unmatched power supply units are
configured.
System power consumption exceeds
the power output capacity limit.
No information is acquired in
checking system power
consumption.
Intel(R) Node Manager is in
Recovery Mode.
Express5800/E120d-M Maintenance Guide
1. POST Error Message
Solution
Contact your service representative.
When Check previous system Config is
enabled in Server of the setup, this
message appears if the configuration was
changed since the previous startup. If this
message appears even when no
configuration change has been made,
contact your service representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
Contact your sales representative.
Check the installation status of power supply
units. Unplug the power cord, wait for at least
30 seconds, then restart the server. If the
same error is detected repeatedly, contact
your sales representative.
Check the jumper switch setting on
motherboard. Unplug the power cord, wait
for at least 30 seconds, then restart the
server. If the same error is detected
repeatedly, contact your sales
representative.