Chapter 3 Appendix
Error Message
C10B
BMC operational code
corrupted.
C10C
BMC update firmware
corrupted.
C10D
Internal Use Area of BMC FRU
corrupted.
BMC SDR Repository empty. An error was detected on BMC SDR.
C10E
C10F
IPMB signal lines do not
respond.
C110
BMC FRU device failure.
BMC SDR Repository failure. Failure was detected in SROM that
C111
C112
BMC SEL device failure.
C113
BMC RAM test error.
BMC Fatal hardware error. A hardware error was detected in
C114
C115
Management controller
not responding
C116
Private I2C bus not
responding.
C117
BMC internal exception
C118
BMC A/D timeout error.
C119
SDR repository corrupt.
C11A
SEL corrupt.
C11B
BMC Mezzanine card is not
found.
C11C
BMC Mezzanine partition is
invalid.
BMC is in Forced Boot Mode. Detected that BMC is in Forced Boot
C11D
C200
The error occurred during
memory configuration
check.
C201
Memory Configuration
change is detected.
Cause
Failed to start BMC firmware.
An illegality was detected in FRU
containing the device information.
Failure of Satellite Management
Controller was detected.
An error was detected in FRU that
contains device information.
stores the SDR.
Device failure was detected in BMC
SEL.
An error was detected in BMC RAM.
BMC.
Management controller does not
respond.
Private I2C bus does not respond.
BMC internal error was detected.
BMC A/D timeout error was
detected.
BMC error or illegal SDR data was
detected.
BMC error or illegal system event log
data was detected.
BMC Mezzanine card is not installed. Contact your sales representative.
A format error was detected in BMC
Mezzanine card.
Mode.
Memory configuration could not be
obtained.
The memory configuration has
changed since the previous startup.
Express5800/E120d-M Maintenance Guide
1. POST Error Message
Solution
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
Update the BMC firmware.
If the same error is detected repeatedly,
contact your sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
Check the jumper switch setting on
motherboard. Unplug the power cord, wait
for at least 30 seconds, then restart the
server. If the same error is detected
repeatedly, contact your sales
representative.
Contact your sales representative.
When Check previous system Config is
enabled in Server of the setup, this
message appears if the configuration was
changed since the previous startup. If this
message appears even when no
configuration change has been made,
contact your service representative.
111