Furuno VR-3000 Operator's Manual page 28

Data recorder simplified voyage data recorder
Hide thumbs Also See for VR-3000:
Table of Contents

Advertisement

Error
code
130
PRC_STATUS_DATIO_FAILURE_
INDICATION
138
PRC_STATUS_CONFIG_FAILURE_
INDICATION
150
PRC_STATUS_CONFIG_INVALID_
SIZE
154
PRC_STATUS_CONFIG_INVALID_
START_TAG
170
PRC_STATUS_FATAL_FAILURE_
INDICATION
186
PRC_STATUS_GRABBER_IMAGE_
TOO_BIG
(Continued on next page)
18
Error codes (con't from previous page)
Name
Description
Problem with
ANALOG/DIGITAL
interface board. Self-test
program run during boot
should indicate which
board.
Unexpected error when
trying to read CONFIG.
Size of CONFIG_area in
DRU is different from
expected one. This
should only happen
during installation/service
and upgrade of software.
CONFIG_area in the DRU
is clean. This should only
happen during
installation/service. This
will also be displayed at
first boot after
CONFIG_area is cleared.
Fatal system error
Video image capture from
radar is larger than
expected.
Action
Replace faulty board.
Check that installed
firmware version is
correct for DRU. IF this
is a new DRU,
CONFIG_area needs to
be cleared.
Clear CONFIG_area
and restart VR-3000/S.
This will install a
"default minimum"
configuration.
Restart VR-3000/S
Call for service.
Check quality of
captured image color
mask (video channels)
and re-adjust frame
grabber.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vr-3000s

Table of Contents