Error Codes - Furuno VR-3000 Operator's Manual

Data recorder simplified voyage data recorder
Hide thumbs Also See for VR-3000:
Table of Contents

Advertisement

3.2 Error Codes

Error codes may appear on the status display on the Power Control Panel to alert to possible
trouble. Below is a list of those codes.
Error
code
---
Hdd
BACKUP_HDD_MISSING
010
PRC_STATUS_DRU_FAILURE_
INDICATION
014
PRC_STATUS_BACKUP_DEVICE_
FAILURE
018
PRC_STATUS STORAGE
BACKUP_CONNECTION_
TIMEOUT
022
PRC_STATUS_STORAGE_DRU_
CONNECTION_TIMEOUT
026
PRC_STATUS_TIMEDIFF_TOO_BIG
034
PRC_STATUS_STORAGE_FAILURE_
INDICATION
(Continued on next page)
16
Error codes
Name
Description
Normal operation after
two minutes
Backup HDD not
connected to VDR.
System is experiencing
trouble communicating
with DRU.
Backup device is either
faulty or not set up
correctly.
This indicates that the
BACKUP has been
disconnected more than
120 seconds.
DRU has been
disconnected more than
120 seconds.
This indicates that the
time difference between
system time and time
supplied by UTC source is
more than one hour.
Problem with data on
storage devices.
Action
None
1) SAVE button pressed
and backup HDD
removed: Replace
backup HDD.
2) Other situations:
Reset VDR. If normal
operation not restored,
request service.
Trouble-shoot
connection from DCU
to DRU (cable,
repeaters and possible
IEEE1394/Firewire
board in DCU).
Replace or reconfigure
backup device
Connect BACKUP HDD
or check LOG and
repair/replace.
Connect DRU again or
check LOG and
repair/replace.
Try to see if the CMOS
clock is set correctly. If
not, set it and restart
VR-3000/S. If yes, find
out why time source
device defined in
WEB_Configurator is
delivered "out of bands"
time info.
Check LOG and
repair/replace. Restart
VR-3000/S

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vr-3000s

Table of Contents