1.3 Operation on Remote Alarm Panel

No power switch is provided on the Remote Alarm Panel; it is turned on and off by the power
switch on the DCU. When the ERROR LED (red) on the Remote Alarm Panel is on, identify the
error by checking code number in the error code tables in Chapter 3. The buttons on the Remote
Alarm Panel work as described in the figure below.
DIMMER:
Adjust panel backlighting;
display software version
no. (pressed together).
TEST: Tests LCD.
Note: The buzzer sounds every time the radar connected to the VDR is turned off. Press the
ACK button to silence the alarm.
SAVE button
The SAVE button functions to stop recording to the backup HDD in the DCU. If an incident occurs,
press this button to stop recording to the backup HDD, and then see paragraph 1.4 for how to
remove the HDD,
Buzzer
SAVE: Stops recording onto the backup HDD.
See the NOTICE below.
Remote Alarm Panel
NOTICE
After pressing the SAVE button, data will
not be recorded. Replace the HDD with
an initialized one, or contact a FURUNO
agent for necessary procedure.
Status Display
LEDs (from left)
SAVE (yellow):
Starts blinking from OFF state
when recording is stopped,
then lights steadily.
If the HDD is disconnected,
this LED lights also.
NORMAL (Green):
On at normal operation.
ERROR (red):
Lights for error.
ACK: Silences buzzer.
7