Connection To A Motor With Encoder (Vector Control) - Mitsubishi Electric FR-A800 Series Instruction Manual

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

2.8
Using encoder-equipped motors together with a Vector control compatible option enables speed, torque, and positioning
control operations under orientation control, encoder feedback control, and full-scale Vector control.
This section explains wiring for use of the FR-A8AP.
 Appearance and parts name of the FR-A8AP
Terminal layout
Symbol
(a)
Mounting hole
(b)
Terminal block
Encoder type selection switch
(c)
(SW3)
(d)
CON2 connector
Terminating resistor selection
(e)
switches (SW1)
Switches (SW2) for manufacturer
(f)
setting
(g)
Board mounted option connector
(h)
LED for manufacturer check
 Terminals of the FR-A8AP
Terminal
symbol
PA1
PA2
PB1
PB2
PZ1
PZ2
PG
SD
PIN
PO
NOTE
• When the encoder's output voltage differs from its input power supply voltage, the signal loss detection (E.ECT) may occur.
• Incorrect wiring or faulty setting to the encoder will cause a fault such as an overcurrent (E.OC[ ]) and an inverter overload
(E.THT). Correctly perform the encoder wiring and setting.
Downloaded from
ManualsNet.com
Connection to a motor with encoder (Vector
control)
(a)
(d)
(f)
PIN and PO
(c)
are not used.
(e)
(a)
Name
Terminal name
Encoder A-phase signal input terminal
Encoder A-phase inverse signal input terminal
Encoder B-phase signal input terminal
Encoder B-phase inverse signal input terminal
Encoder Z-phase signal input terminal
Encoder Z-phase inverse signal input terminal
Encoder power supply (positive) input terminal Input terminal for the encoder power supply.
Encoder power supply ground terminal
Not used.
search engine
Front view
(h)
O
1
N
2
SW2
SW3
(b)
Description
Used for installation to the inverter.
Connected with the encoder.
Switches the encoder type (differential line driver/complementary).
Used for extension.
Switch ON or OFF the internal terminating resistor.
Do not change the initial setting (both SW2-1 and SW2-2 switches: OFF
).
O
1
N
2
Used to connect this product to the option connector on the inverter.
Not used.
A-, B- and Z-phase signals are input from the encoder.
Connect the external power supply and the encoder power cable. When the
encoder output is the differential line driver type, only 5 V can be input. Make
the voltage of the external power supply same as the encoder output
voltage. (Check the encoder specification.)

2.8 Connection to a motor with encoder (Vector control)

Rear view
(a)
(a)
Description
2. INSTALLATION AND WIRING
1
2
3
4
(a)
5
6
7
(a)
8
Refer to page
91
9
88
88
10
19
87

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents