Download Print this page

EdilKamin PELLKAMIN 10 EVO PLUS Installation, Use And Maintenance Manual page 63

Wood pellet insert

Advertisement

MESSAGE
PROBLEM
displays when the combustion
A01
air intake is below the set level
displays when the logic board
A02
is not detecting the right fumes
fan speed
displays when the
thermocouple detects a fume
A03
temperature lower than the set
value and interprets this as the
absence of flame
displays when ignition times
A04
out unsuccessfully
Shutdown due to air flow rate
A05
sensor breakage
displays when the logic board
determines that the fumes
A06
thermocouple is broken or
disconnected
Shut-down due to exceeding
A07
maximum fumes temperature.
Switching OFF due to excessive
A08
overheating of the product
Shutdown due to gearmotor fail-
A09
ure.
Switching OFF due to circuit
A10
board overheating.
Switching OFF due to the inter-
A11
vention of the safety pressure
switch.
IN THE EVENT OF PROBLEMS
SOLUTION
There are two possibilities:
NO flame:
• Check that the burning pot is seated properly and clean
• Check that there are pellets in the tank and burning pot
• Try switching it on with a solid ecological igniter (contact
the technician beforehand and follow the instructions of
the igniter supplier very carefully).
The operation must be regarded purely as a trial under the
technician's guidance.
USER/INSTALLER
Check that the combustion chamber door is closed
Check the regular maintenance of the product
Check that smoke discharge and combustion air
ducts are clean.
Contact the technician
Check that there are pellets in the tank
Contact the technician
Contact the technician
Contact the technician
Check the type of pellet (contact the technician if in
doubt)
contact the technician
see A07
Contact the technician
Contact the technician
Ensure the product and flue are clean
Contact the technician
63