WARNING
Fire Risk
Do NOT operate appliance:
• With appliance door open.
• Firepot floor open.
• Cleaning slide plates open.
Do NOT store fuel:
• Closer than required clearances to com-
bustibles to appliance
• Within space required for loading or ash
removal.
Back side of Firepot
Figure 25.1 - DO NOT LEAVE FIREPOT FLOOR OPEN
I. Frequently Asked Questions
1. Metallic noise.
2.
Ash buildup on glass.
.
Glass has turned dirty.
4.
Fire has tall flames with black tails and is lazy.
5.
Smokey start-up or puffs of smoke from the airwash. 5. Either the firepot is dirty or there is too much fuel at
6.
Large flame at start-up.
Page 26
Firepot floor left open
ISSUES
1. Noise is caused by metal expanding and contracting as
it heats up and cools down, similar to the sound pro-
duced by a furnace or heating duct. This noise does not
affect the operation or longevity of your appliance.
2. This is normal. Clean the glass.
. Excessive build up of ash. The lower burn settings will
produce more ash, the higher burn settings produce
less. The more it burns on low the more frequent clean-
ing of the glass is required.
4. The feed rate needs to be reduced or the firepot needs
cleaning. Heat exchanger or exhaust blower needs
cleaning.
start-up and not enough air. Close down feed rate 1/4
inch (6mm) at a time until this no longer happens.
6. This is normal. Flame will settle down once the fire is
established.
7014-083C
SOLUTIONS
October 26, 2006