Monitor Setting Display - Delta Electronics ASDA-AB Series User Manual

Advanced ac servo drive for general purpose applications
Table of Contents

Advertisement

Chapter 4 Display and OperationASDA-AB Series
Display Message

4.3.5 Monitor Setting Display

When the AC servo drive is applied to power, the LCD display will show the monitor function codes for
approximately one second and then enter into the monitor mode. In monitor mode, in order to change
the monitor status, the users can press UP or DOWN arrow key or change parameter P0-02 directly to
specify the monitor status. When the power is applied, the monitor status depends on the setting value
of P0-02. For example, if the setting value of P0-02 is 2 when the power is applied, the monitor function
will be Pulse counts of pulse command, the C.P monitor codes will first display and then the pulse
number will display after.
P0-02
Display Message
Setting
0
1
2
3
4
5
6
7
8
4-4
Negative value display. When the parameter setting is greater
than four digits (for the setting value within the range of less than
five decimal places), after the display value is set, continuously
press SHIFT key for many times and then the lit decimal points
are used to indicate a negative value.
Negative value display. When the parameter setting is less than
five digits (for the setting value within the range of five decimal
places), after the display value is set, continuously press SHIFT
key for many times and then the negative sign will show up to
indicate a negative value.
Motor feedback pulse number (absolute
value)
Motor feedback rotation number
(absolute value)
Pulse counts of pulse command
Rotation number of pulse command
Position error counts
Input frequency of pulse command
Motor speed
Speed input command
Speed input command
Description
Description
Revision November 2014
Unit
pulse
rev
pulse
rev
pulse
r/min
r/min
Volt
r/min

Advertisement

Table of Contents
loading

Table of Contents