Molded-Case Circuit Breaker And Fuse Current Recommended Value; Emi Filter Selection - Delta Electronics ASDA-AB Series User Manual

Advanced ac servo drive for general purpose applications
Table of Contents

Advertisement

2.5

Molded-case Circuit Breaker and Fuse Current Recommended Value

 Caution: Please use molded-case circuit breaker and fuse which are recognized by and comply with the UL or
CSA standards.
Servo Drive Model
Operation Mode
ASD-A0111-AB
ASD-A0211-AB
ASD-A0411-AB
ASD-A0121-AB
ASD-A0221-AB
ASD-A0421-AB
ASD-A0721-AB
ASD-A1021-AB
ASD-A1521-AB
ASD-A2023-AB
ASD-A3023-AB
When using a GFCI (Ground Fault Circuit Interrupter), select a current sensor with
NOTE
sensitivity of 200mA, and not less than 0.1-second detection time to avoid nuisance
tripping.
2.6

EMI Filter Selection

AC Servo Drive - EMI Filter Cross Reference
Item
Power
1
100W
2
100W
3
200W
4
200W
5
400W
6
400W
7
750W
8
1000W
9
1500W
10
2000W
11
3000W
Revision November 2014
Chapter 2 Installation and StorageASDA-AB Series
Recommended Breaker
General
10A
10A
10A
5A
5A
10A
10A
15A
20A
30A
30A
Servo Drive Model
ASD-A0111-AB
ASD-A0121-AB
ASD-A0211-AB
ASD-A0221-AB
ASD-A0411-AB
ASD-A0421-AB
ASD-A0721-AB
ASD-A1021-AB
ASD-A1521-AB
ASD-A2023-AB
ASD-A3023-AB
Recommended Fuse (Class T)
General
10A
10A
10A
5A
6A
10A
20A
25A
40A
50A
70A
Recommended EMI Filter
08TDT1W4S
08TDT1W4S
08TDT1W4S
08TDT1W4S
08TDT1W4S
08TDT1W4S
20TDT1W4D
20TDT1W4D
20TDT1W4D
20TDT1W4D
20TDT1W4D
FootPrint
N
N
N
N
N
N
N
N
N
N
N
2-5