Power Supply Cord Replacement; On/Off Switch Replacement - Graco A Series Instructions-Parts List Manual

120 v ac, 15 amp 3000 psi (210 bar) maximum working pressure
Hide thumbs Also See for A Series:
Table of Contents

Advertisement

WARNING
Before doing this procedure, follow the
Relief Procedure W arning on page 24 to reduce
the risk of a fluid injection injury , splashing in the
eyes or on the skin, injury from moving parts, or
electric shock. Unplug the sprayer!
Refer to Fig 26–1.
1. Remove the pressure control cover and screws.
2. Disconnect the power supply cord lead from the ON/
OFF switch (303), the white wire going to the bridge
(308), and the green wire to the grounding screw
(343) and lockwasher (327).
3. Loosen the strain relief bushing (328). Remove the
power supply cord (311).
4. Install the new cord (311) in the reverse order of dis-
assembly.
5. Reinstall the cover and screws.
WARNING
Before doing this procedure, follow the
Relief Procedure W arning on page 24 to reduce
the risk of a fluid injection injury , splashing in the
eyes or on the skin, injury from moving parts, or
electric shock. Unplug the sprayer!
Refer to Fig 26–2 except where noted.
1. Remove the pressure control cover and screws.
2. Use a needle nose pliers to disconnect the upper ter-
minal wire from the microswitch (302) for ease in re-
moving the ON/OFF switch (303). See Fig 26–1.
3. Use pliers to disconnect the two black wires from the
ON/OFF switch (303). Refer to Fig 26–1.
4. Use a 5/8" socket wrench to loosen and remove the
nut and rubber boot (304) from the top of the pres-
sure control. Remove the switch guard (305).
5. Remove the ON/OFF switch.
6. Install the new switch so the internal tab of the anti–
rotation ring (W) engages with the vertical groove in
the threads of the switch, and the external tab en-
gages with the blind hole (D) of the pressure control.
7. Install the switch guard (305), aligning the internal
tab with the groove in the threads.
307–958

POWER SUPPLY CORD REPLACEMENT

Pressure

ON/OFF SWITCH REPLACEMENT

Pressure
343,327
Fig 26–1
8. Powder the inside of the rubber boot (304) with tal-
cum, then shake excess out of boot.
9. Install the nut and rubber boot and tighten.
10. Reconnect the wires to the ON/OFF switch (303) and
reconnect the wire to the microswitch (302).
11. Reinstall the pressure control cover and screws.
D
Fig 26–2
303
308
328
311
304
305
W
303

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lopro 1000231-094