Maintenance contract
You can enter into a maintenance contract
with the concerned Kaercher Sales Office
for the machine.
Frost protection
The machine should be stored in frost-free
rooms. In case there is frosting risk, for e.g.
if the machine is installed in open areas,
then the machine must first be emptied and
flushed using an anti-freezing agent.
Drain water
Screw off water supply hose and high
pressure hose.
Operate device for max. 1 minute until
the pump and conduits are empty.
Flush device with anti-freeze agent
Note: Observe handling instructions of the
anti-freeze agent manufacturer.
Fill in normal anti-frost agents in the
swimmer tank right until the top.
Place the collection trough under the
high pressure exit.
Switch on the appliance and let it run
until the safety mechanism against lack
of water in swimmer tank gets activated
and the machine is switched off.
A certain corrosion protection is achieved
with this as well.
Troubleshooting
DANGER
Risk of injury! The main switch is to be
switched off with all repair work.
A Error number
B Number of currently present errors
Error
Error description
number
01
Control voltage is miss-
ing
02
Display, no communi-
cation
10
Motor protection switch
high pressure pump 1
11
Motor protection switch
high pressure pump 2
12
Motor protection switch
high pressure pump 3
13
Motor protection switch
high pressure pump 4
14
Motor protection switch
of the frequency invert-
er or frequency inverter
not ready
18
Winding protection
contact high pressure
pump 1
19
Winding protection
contact high pressure
pump 2
20
Winding protection
contact high pressure
pump 3
21
Winding protection
contact high pressure
pump 4
26
Motor protection switch
advance pressure
pump
30
Switch "On" constantly
occupied (control in-
put)
31
Switch "On" constantly
occupied (display)
32
Switch "Off" constantly
occupied (control in-
put)
40
Water shortage
41
Water temperature is
too high
42
Leakage switch-off 1
(e.g. hose burst)
43
Leakage switch-off 2
(minor leakage)
9
-
EN
45
Pressure too high
(> 300 bar)
46
Flowmeter issues in-
correct signal
47
Overflow valve adjust-
ed incorrectly
48
HDC type set incorrect-
ly
49
Flowmeter does not
emit signal
50
Pressure sensor for
high pressure does not
transmit signal
52
Temperature sensor
does not transmit sig-
nal
– Error type 1: Emergency operation of
Error
the system with remaining high pres-
type
sure pumps.
2
– Error type 2: The operating readiness of
the system is switched off and the high
2
pressure pumps are shut off.
– If one of the above errors occurs, the
1
appliance can be restarted after the er-
ror has been corrected by activating the
1
release switch.
Note: The 40 most recently occurred errors
are saved with the respective date and time
1
and can be shown on the display.
1
2
1
1
A Date of error event
B Time of error event
C Error number
1
D List location of error
E Number of saved errors
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
25