Troubleshooting - Kärcher HDC 60/12 Advanced Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17
Maintenance contract
You can enter into a maintenance contract
with the concerned Kaercher Sales Office
for the machine.
Frost protection
The machine should be stored in frost-free
rooms. In case there is frosting risk, for e.g.
if the machine is installed in open areas,
then the machine must first be emptied and
flushed using an anti-freezing agent.
Drain water
 Screw off water supply hose and high
pressure hose.
 Operate device for max. 1 minute until
the pump and conduits are empty.
Flush device with anti-freeze agent
Note: Observe handling instructions of the
anti-freeze agent manufacturer.
 Fill in normal anti-frost agents in the
swimmer tank right until the top.
 Place the collection trough under the
high pressure exit.
 Switch on the appliance and let it run
until the safety mechanism against lack
of water in swimmer tank gets activated
and the machine is switched off.
A certain corrosion protection is achieved
with this as well.

Troubleshooting

DANGER
Risk of injury! The main switch is to be
switched off with all repair work.
A Error number
B Number of currently present errors
Error
Error description
number
01
Control voltage is miss-
ing
02
Display, no communi-
cation
10
Motor protection switch
high pressure pump 1
11
Motor protection switch
high pressure pump 2
12
Motor protection switch
high pressure pump 3
13
Motor protection switch
high pressure pump 4
14
Motor protection switch
of the frequency invert-
er or frequency inverter
not ready
18
Winding protection
contact high pressure
pump 1
19
Winding protection
contact high pressure
pump 2
20
Winding protection
contact high pressure
pump 3
21
Winding protection
contact high pressure
pump 4
26
Motor protection switch
advance pressure
pump
30
Switch "On" constantly
occupied (control in-
put)
31
Switch "On" constantly
occupied (display)
32
Switch "Off" constantly
occupied (control in-
put)
40
Water shortage
41
Water temperature is
too high
42
Leakage switch-off 1
(e.g. hose burst)
43
Leakage switch-off 2
(minor leakage)
9
-
EN
45
Pressure too high
(> 300 bar)
46
Flowmeter issues in-
correct signal
47
Overflow valve adjust-
ed incorrectly
48
HDC type set incorrect-
ly
49
Flowmeter does not
emit signal
50
Pressure sensor for
high pressure does not
transmit signal
52
Temperature sensor
does not transmit sig-
nal
– Error type 1: Emergency operation of
Error
the system with remaining high pres-
type
sure pumps.
2
– Error type 2: The operating readiness of
the system is switched off and the high
2
pressure pumps are shut off.
– If one of the above errors occurs, the
1
appliance can be restarted after the er-
ror has been corrected by activating the
1
release switch.
Note: The 40 most recently occurred errors
are saved with the respective date and time
1
and can be shown on the display.
1
2
1
1
A Date of error event
B Time of error event
C Error number
1
D List location of error
E Number of saved errors
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
25

Advertisement

Table of Contents
loading

Table of Contents