Haier AP88NACBEA Operation Manual

Cabinet unit
Hide thumbs Also See for AP88NACBEA:

Advertisement

Quick Links

Cabinet unit
Operation Manual
AP88NACBEA
AU88NATBEA
No.0010573003
CONTENTS
R
MODE FAN
SWING
TEMP
CLOCK
SET
TIMER
SLEEP
FILTER RESET
RESET
ON/OFF
1
2-3
4-5
6-10
11
12-13
14
15
16
17
18-30
31-32

Advertisement

Table of Contents
loading

Summary of Contents for Haier AP88NACBEA

  • Page 1: Table Of Contents

    Cabinet unit Operation Manual AP88NACBEA AU88NATBEA MODE FAN TEMP CLOCK TIMER FILTER RESET ON/OFF No.0010573003 CONTENTS Operation points Name of Parts Safety Precautions Operation instruction Users' Attention SWING SLEEP RESET Maintenance Trouble shooting When problems occur When troubles occur Installation instruction...
  • Page 2: Operation Points

    ON/OFF button to turn off the unit after power failure resumes.
  • Page 3: Name Of Parts

    Name of Parts Indoor unit Inlet grill Outdoor unit Air inlet Air inlet Note: Open the power switch 12 hours before the unit running.Do not cut off the power when short time stop the unit (like one day and one night ),this is to protect the compressor.
  • Page 4: Name Of Parts

    Name of Parts 1.ON/OFF button Used to turn on/off unit 2.Temperature display 3.Clock display 4.Timer ON/OFF display 5.Humidity display 6.Air filter cleaning display When there is too much dust collected on the air inlet, the wire controller will show this display to remind the user to clean the air inlet.
  • Page 5: Safety Precautions

    Then consult your dealer. If continuing the operation without removing the cause, it may cause trouble, electric shock or fire. Notice Do not use water to clean the air conditioner. It may cause electric shock.
  • Page 6 Creepage or short-circuit. Safety precautions when moving, reinstalling and repairing the air conditioner Do not refit the air conditioner. When repair is needed, please contact your dealer.
  • Page 7: Operation Instruction

    RESET ON/OFF About FAN operation: FAN operation refers the air conditioner does not perform COOLING and HEATING operation, but FAN operation. In this mode, the air conditioner cannot perform AUOT FAN operation, and does show the temperature value on the wire controller.
  • Page 8 + 2*, the unit will operate in mild dehumidifying operation. In Heating operation, after start the unit, the air conditioner will sending warm air a moment later to prevent the cold air blowing out. In Dehumidifying, when the room temperature drops...
  • Page 9: Sleep Operation

    Operation instruction Before going to bed, you can press the SLEEP button, the air conditioner will operate in comfort sleep mode to make you have a sound sleep. should calibrate the clock first, otherwise, the SLEEP function will be out of order.
  • Page 10: Timer On/Off Function

    (referring to page 4). When you wake up in the morning, before going back to home after work or after going to bed, you can let your air conditioner automatically turn on or turn off. 1.Turn on the unit After turning on the unit, set the desired working mode.
  • Page 11: Operation Instruction

    Operation instruction MODE SWING TEMP CLOCK TIMER SLEEP ROOM HEAT FILTER RESET RESET ON/OFF 3.Set time Press the time adjusting button Each press, the set time increases 10 minutes. If depress the button, the time will increase rapidly. Each press, the set time decreases 10 minutes. If depress the button, the time will decrease rapidly.
  • Page 12: Users' Attention

    The air conditioner can only be used in air conditioning. It can not be used in other purpose. Do not use the air conditioner in some specific purpose, such as storage or protect food, animals, plants, precise instrument and...
  • Page 13: Maintenance

    Clean it with warm and wet cloth or with neutral detergent, then wipe it dry with clean and soft cloth. If air conditioner is very dirty, clean it with cloth soaked in neutral detergent,then wipe off the detergent with clean water.
  • Page 14 Maintenance After season maintenance Let the unit run in Fan mode for half a day in a fine weather to dry completely the unit inside. Turn off the unit and pull out power plug. There might be certain power consumption even if unit is stopped.
  • Page 15: Trouble Shooting

    Trouble shooting Followings are not problems Sound of water flowings are not problems. Sound of cracking is heard. Smells are generated. During operation, white fog or steam comes out of indoor unit. In cooling operation, unit switches to fan operation. Unit will not restart after stop.
  • Page 16: When Problems Occur

    The fuse type on indoor unit PC board is T3.15A/250V. The fuse type of fan controlle wire is T3.15A/250V. The fuse type on outdoor unit PC board is T6.3A/250V. Air conditioner won't start. Is city power supply normal? Is leakage current breaker...
  • Page 17: When Troubles Occur

    If finding any abnormal phenomena (e.g. smell of burnt), please cut off power and ask help for after-sales service personnel. If still use the air conditioner under this condition, the unit may be damaged and maybe cause electric shock or fire, etc. accidents.
  • Page 18: Installation Instruction

    Install the air conditioner to a place where can definitely stand its weight. The air conditioner can not be installed on a nonmetal bracket (such as theft guard net). Places not firm enough will cause drop down of unit resulting in body hurt.
  • Page 19: Standard Accessories

    Installation instruction This manual can not include all kinds of conditions, if you have new requirements and questions, please contact with local Haier Sales Center. Before installing the unit, please read this manual carefully. Improper installation may cause accidents and make unit damage or death.
  • Page 20: Installation Procedure

    Installation procedure 1. Before installation [Before finishing installation, do not throw the attached installation parts away.] Confirm the route to carry the units to the installation place. Do not remove the package of the unit, before carrying it to the installation place. When have to remove the package, use a soft material or protection board with rope to lift the unit to prevent the unit from damage or bumping scrape.
  • Page 21: Installation Of Indoor Unit

    Installation procedure Installation of indoor unit Selection of installation place Place where it is easy to route drainage pipe and outdoor piping. Place away from heat source and with less direct sunlight. Place where cool and warm air could be delivered evenly to every corner of the room. Place near power supply socket.
  • Page 22 Installation procedure Installation of fall-prevention fitting metal: Fix the fitting metal to the wall by screws so that there is no clearance between them. With the unit set up vertically, fix the fitting metal to the unit with screws while making an adjustment at the long portion of the hole so that there is no clearance between the upper surface and the fitting metal.
  • Page 23 Installation procedure 2. Piping connection of indoor unit Arrangement of piping and drainage pipe Cut away, with a hammer or a saw, the lid for piping according to piping direction. Insulation material Copper tube According to the piping method, connect the piping on indoor unit with union of connecting pipe. Arrange the piping as per the wall hole and bind drain hose connecting electric cable and piping together with polyethylene tape.
  • Page 24 * After finishing connection of connecting pipe, please do thermal insulation treatment by using the attached thermal insulation material. Otherwise, it may cause water leakage. Setting of wire controller dial switch Setting of this series of air conditioner dial switch: 1, ON; 2, OFF; 3, ON; 4, ON. Outdoor unit...
  • Page 25: Selection Of Installation Site

    Installation procedure Selection of installation site It should be installed at places where it is firm enough to withstand the weight of the air conditioner to prevent falling. Typhoon and earthquake prevention. It should be installed according to specific requirements.
  • Page 26: Outdoor Unit

    Installation procedure Refer to the following figure for the distance between the foundation bolts. (2)When the refrigerant pipe is connected from the bottom of the unit,the unit should be raised at least 500mm(see the figure below) (3)In snowy regions,snow-proof facilities should be used(see the figure below).
  • Page 27 Installation procedure (6) During welding,the gas pipe valve must be cooled down with a wet cotton cloth. During welding of the distribution pipe 1.In case of brazing weld of joint,nitrogen must be filled in the pipe to prevent oxidization. 2.The refrigerant pipe should be newly-made and clean.During installation,do not let water and other substance into the pipe.
  • Page 28 Installation procedure Matters needing attention Never use oxygen,flamable and poisonous gases for the leak test. Indoor Outdoor Tightly closed Solder joint Tightly Solder joint closed Indoor unit Detailed diagram of the three-way valve To the gauge distributor (Liquid side)access hole (Liquid side)three-way valve Field tube installation...
  • Page 29 Installation procedure Check for leakage In the case of pressure decrease during steps 1 to 3 ,check the joints with the ear,hand or soapsuds for leakage.Repair it by welding or tighten the connecting nut up. Vacuum Pumping Use vacuum pump to evacuate the air.Never use the refrigerant for the evacuation. Drain off the nitrogen gas after the leak test and then connect the vacuum pump as shown in the figure below.
  • Page 30 Installation procedure Refrigrant must be added in liquid state. Refrigerant bottle swith or without a siphon tube can be refilled with refrigerant upright or upside down,Respectively. Refilling of refrigerant After the vacuum pumping,replace the vacuum pump with the refrigerant pump and refill refrigerant. Calculation of refrigerant quantity The factory filled refrigerant into the piping excludes the part of pipes according to be refilled on the site.
  • Page 31: Installation Procedure

    When connecting the indoor & outdoor wire, check the number of the indoor & outdoor terminals, the terminals with the same number connected together with one wire. Incorrect wiring will damage the controller of the air conditioner or make the unit work abnormally.
  • Page 32: Others

    5m, please overstriking wire. Air conditioner must use an exclusive line (over 30A) When installation air conditioner in a wet place, try to use a circuit breaker against Current leakage. For installation in other places, use circuit breaker as far as possible.