Haier AP71DFCHRA Operation Manual And Installation Manual

Haier AP71DFCHRA Operation Manual And Installation Manual

Packaged type room air conditioner

Advertisement

Quick Links

PACKAGED TYPE ROOM AIR CONDITION
OPERATION MANUAL AND INSTALLATION MANUAL
Please read this manual before using the air conditioner.
Keep this manual for future reference.
This appliance is filled with R32.
0011509384
AP71DFCHRA/1U71RECFRA
AP24DFCHRA/1U24RECFRA
ER

Advertisement

loading

Summary of Contents for Haier AP71DFCHRA

  • Page 1 PACKAGED TYPE ROOM AIR CONDITION OPERATION MANUAL AND INSTALLATION MANUAL AP71DFCHRA/1U71RECFRA ● AP24DFCHRA/1U24RECFRA Please read this manual before using the air conditioner. Keep this manual for future reference. This appliance is filled with R32. 0011509384...
  • Page 2 Contents ....................... PARTS AND FUNCTIONS OPERATION..........................CAUTIONS..........................TROUBLE SHOOTING......................20 INDOOR AND OUTDOOR UNIT INSTALLATION..............................MAINTENANCE AND WIFI FUNCTION Read the precautions in this manual This appliance is filled with R32. carefully before operating the unit. Keep this manual where the user can easily find it. WARNING: ·...
  • Page 3 Loading and Unloading/Transporting Management/Storage Requirements The products shall be carefully handled during loading and unloading. Rude and barbarous handling such as kicking, throwing, dropping, bumping, pulling and rolling is not allowed. The workers engaged in loading and unloading must be subject to necessary trainings on the potential hazards caused by barbarous handling.
  • Page 4 Procedures: operation shall be made as per controlled procedures to minimize the probability of risks. Area: area shall be divided and isolated appropriately, and operation in an enclosed space shall be avoided. Before the refrigeration system is started or before hot working, ventilation or opening of the area shall be guaranteed.
  • Page 5 • Electrical Safety Requirements Note: The surrounding conditions (ambient temperature, direct sunlight and rainwater) shall be noticed during electrical wiring, with effective protective measures being taken. Copper wire cable in line with local standards shall be used as the power line and connector wire. Both the indoor unit and outdoor unit shall be reliably earthed.
  • Page 6 Fixation The support of the outdoor unit shall be fixed onto the wall surface, and then the outdoor unit shall be fixed onto the support horizontally. In case the outdoor unit is wall-mounted or roof-mounted, the support shall be firmly fixed, to avoid the damage of strong wind.
  • Page 7 Relocation Procedures Note: in case relocation is required, the joint of evaporator gas/liquid pipes of the indoor unit shall be cut off with a cutting knife. Connection is only allowed after re-flaring (the same to the outdoor unit). Maintenance Instructions Maintenance Precautions Precautions •...
  • Page 8 Inspection on Maintenance Environment • Before operation, the refrigerant leaked in the room is not allowed. • The area of the room in which maintenance is made shall be in line with the nameplate. • Continuous ventilation shall be maintained during maintenance. •...
  • Page 9 Safety Principles • During product maintenance, favorable ventilation shall be guaranteed at the maintenance site, and the close of all the doors/windows is not allowed. • Operation with open fire is not allowed, including welding and smoking. The use of phones is also not allowed.
  • Page 10 Removal and Vacuumizing The maintenance or other operations of the refrigeration circuit shall be made as per conventional procedures. Moreover, the flammability of refrigerant shall also be mainly considered. The following procedures shall be followed: • Refrigerant clearing; • Pipeline purification with inert gas; •...
  • Page 11 In case the vacuum state cannot be reached, vacuumizing shall be carried out from numerous positions, to pump the refrigerant in each part of the system out; It shall be guaranteed that the capacity of cylinders is sufficient before recovery; The recovery equipment shall be started and operated as per the operation instructions of the manufacturer;...
  • Page 12 Parts and Functions Indoor Unit AIR FILTER (INSIDE) Remote controller Outer side of the controller ON / OFF button Display of each functio status 7. Operation mode display 8. CLOCK display 9. TEMP display TIMER 10. Humidity display 11. FAN SPEED display 12.
  • Page 13 HEALTH button (Press the HEALTH button in the shutdown state to enter Fan mode) BNT button (BNT function is not available) A-b yard(Only A yard is available) SMART SMART...
  • Page 14 Operation Operation COOL,HEAT and DRY Operation COOL,HEAT and DRY Operation TURBO/QUIET Operation Unit start. Select operation mode. Press the COOL button on TURBO Operation TURBO the remote controller. TURBO TURBO QUIET Operation SELF CLEAN SELF CLEAN QUIET Operation: You can use this function when silence is needed for rest or Press the HEAT button on the remote controller.
  • Page 15 You can control the unit temp. by the panel "<"">" independently . Every time the button is pressed, temp. setting increases/ decreases 0.5ºC. TURBO The range of setting temperature is 16℃-30℃. SELF CLEAN SMART...
  • Page 16 TIMER TURBO SMART SELF CLEAN...
  • Page 17 TIMER SMART SMART...
  • Page 18 - Press the HEALTH button in the shutdown state to enter Fan mode. - Press the HEALTH button in the poweron state to turn on Health function. SMART SMART...
  • Page 19 Operation For Smart Use of the Air Conditioner Air Filter cleaning 1.Close the unit and turn off the power. 2.Remove the filter as shown in the below picture Contains fluorinated greenhouse gases covered by the Kyoto Protocol 3.Clean the filter Use a vacuum cleaner to remove dust, or wash the filter with water.
  • Page 21 Trouble shooting Phenomenon Cause or check points s the air filter dirty?normally it should be cleaned every 15 days. Are there any ostacles before inlet and outlet? Is temperature set correctly ? Are there some doors or windows left open? Is there any direct sunlight through the window during the cooling Poor cooling or poor operation(use curtain)
  • Page 22 Installation Precautions Caution This manual describes the use of Qingdao Haier Air-conditioner Limited Company set up the installation of tools for air conditioners to install the method. 1. In order to make the air conditioner work well, please the indoor machine and the outdoor machine is 10 install the air conditioner in accordance with the meters.
  • Page 23 Drawing for the Installation of Indoor and outdoor Unit The models adopt HFC free refrigerant R32 More than 10cm Back Arrangement of piping directions More than 10cm Left Right More than 10cm Guard ring Front No barrier in the front LEFT BACK RIGHT...
  • Page 24 Arrangement of the drain hose Diameter of Copper tube(mm) Tightening torque(N.m) Drain hose shall be placed in under place. 18- 20 There should be a slope when arrange drain hose. Avoid up and down waves in drain hose. If humidity is high, drain 30- 35 pipe(especially in room and indor unit) must be coverd with installation material.
  • Page 25 Connection Loosen the screws on terminal block and insert the plugs fully into terminal block, then tighten the screws. Insert the cable according to terminal number in the same manner as the indoor Fixed the unit unit. First, the metal mounting bracket is fixed on the wall, the expansion bolts of the If wiring is not correct, proper operation can not be carried out and controller may be damaged.
  • Page 26 Caution Maintenance If the refrigerant of the air conditioner leaks, it is necessary to discharge all the refrigerant. Vacuumize rst, then charge the liquid refrigerant into air conditio- Cleaning of the unit ner according to the amount marked on the name plate. Please do not let other cooling medium, except speci ed one (R32), or air enter into the cooling circulation system.
  • Page 27 Maintenance before use of the season Check the inlet and outlet of indoor and outdoor machines for obstructions, so as to avoid reducing work efficiency. Haier Address:No.1 Haier Road,Hi-tech Zone,Qingdao 266101 P.R.China Contacts: TEL +86-532-8893-6943;FAX +86-532-8893-1010 Website: www.haier .com...