Max. torque
Chuck
4.2
Noise information and vibration values
The sound pressure and vibration values given in these instructions have been measured in accordance
with a standardized test and may be used to compare one electric tool with another. They may be used
for a preliminary assessment of exposure. The data given represents the main applications of the electric
tool. However, if the electric tool is used for different applications, with different accessory tools, or is poorly
maintained, the data may vary. This may significantly increase exposure over the total working period. An
accurate estimation of exposure should also take into account the times when the power tool is switched
off, or when it is running but not actually being used for a job. This may significantly reduce exposure over
the total working period. Identify additional safety measures to protect the operator from the effects of noise
and/or vibration, for example: maintenance of the electric tool and the accessories, keeping the hands warm,
organization of work patterns.
Noise information in accordance with EN 62841
Sound (power) level (L
Uncertainty for the sound power level (K
Emission sound pressure level (L
Uncertainty for the sound pressure level (K
Sound (power) level (L
Uncertainty for the sound power level (K
Emission sound pressure level (L
Uncertainty for the sound pressure level (K
Total vibration
Vibration emission value
for screwdriving without
impact action
(a
)
h
WA
Uncertainty for screw-
driving
5

Operation

5.1
Preparations at the workplace
CAUTION
Risk of injury! Inadvertent starting of the product.
▶ Unplug the supply cord before making adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
5.1.1
Working safely with the universal hook
▶ Before beginning the work, make sure that the universal hook is securely attached to the screwdriver.
▶ Lay the screwdriver down in a safe place when it is not in use for a long period.
5.1.2
Forward / reverse
The control switch is locked when the forward / reverse switch is in the middle position (safety lock).
*2021370*
Printed: 22.10.2018 | Doc-Nr: PUB / 5135866 / 000 / 03
SD 2500
19 Nm
Hex socket
/
"
1
4
)
WA
)
WA
)
pA
)
pA
)
WA
)
WA
)
pA
)
pA
SD 2500
2.5 m/s²
1.5 m/s²
2
2021370
SD 5000
9.5 Nm
Hex socket
/
"
1
4
SD 2500
100 dB(A)
3 dB(A)
89 dB(A)
3 dB(A)
SD 6000
98 dB(A)
3 dB(A)
85 dB(A)
3 dB(A)
SD 5000
2.5 m/s²
1.5 m/s²
SD 6000
7.9 Nm
Hex socket
/
"
1
4
SD 5000
98 dB(A)
3 dB(A)
87 dB(A)
3 dB(A)
SD 6000
3 m/s²
1.5 m/s²
English