Operating & Maintenance Manual

Prior to Starting

1. Place the unit in a position that is as level as possible. The design of the unit
permits a 15 degree lengthways and sideways limit on out of level operation.
When the unit has to be operated out of level, it is important to keep the engine
oil level near the high level mark (with the unit level).
Do not overfill either the engine or the compressor with oil.
2. Check the engine lubrication oil in accordance with the operating instructions
in the Engine Operator's Manual.
3. Check the compressor oil level in the sight glass located on the separator tank.
Liquid level should be in the green zone.
4. Check the diesel fuel level. A good rule is to top up at the end of each working
day. This prevents condensation from occurring in the tank.
Use only a No. 2–D diesel fuel oil with a minimum octane number of 45
and a sulphur content not greater than 0,5%.
When refuelling:-
5. Drain fuel filter water separator of water ensuring that any released fuel is
safely contained.
6. Check the radiator coolant level (with the unit level).
7. Open the service valve(s) to ensure that all pressure is relieved from the
system. Close the service valve(s).
36
!
!
!
switch off the engine.
do not smoke.
extinguish all naked lights.
do not allow the fuel to come into contact with hot surfaces.
wear personal protective equipment.
CAUTION
CAUTION
CAUTION
Operating Instructions