Page 1
HARDWARE INSTALLATION GUIDE Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07 Publication Date: 25 January 2019...
Page 2
Trademarks ARRIS, the ARRIS logo, Ruckus, Ruckus Wireless, Ruckus Networks, Ruckus logo, the Big Dog design, BeamFlex, ChannelFly, EdgeIron, FastIron, HyperEdge, ICX, IronPoint, OPENG, SmartCell, Unleashed, Xclaim, ZoneFlex are trademarks of ARRIS International plc and/or its affiliates.
Safety labels are also attached directly to products to warn of these conditions or situations. Command syntax conventions Bold and italic text identify command syntax components. Delimiters and operators define groupings of parameters and their logical relationships. Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Access to Release Notes requires an active support contract and Ruckus Support Portal user account. Other technical documentation content is available without logging into the Ruckus Support Portal. White papers, data sheets, and other product documentation are available at https://www.ruckuswireless.com. Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Ruckus products, including: • Technical Documentation—https://support.ruckuswireless.com/documents • Community Forums—https://forums.ruckuswireless.com/ruckuswireless/categories • Knowledge Base Articles—https://support.ruckuswireless.com/answers • Software Downloads and Release Notes—https://support.ruckuswireless.com/software • Security Bulletins—https://support.ruckuswireless.com/security Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 10
Using these resources will help you to resolve some issues, and will provide TAC with additional data from your troubleshooting analysis if you still require assistance through a support case or RMA. If you still require help, open and manage your case at https:// support.ruckuswireless.com/case_management Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
What’s new in this document ................9 What’s new in this document There are no enhancements in this edition. Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 12
About this Document What’s new in this document Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Ruckus ICX 7450 customizable switches The Ruckus ICX 7450 base systems do not ship with power supplies, fans, stacking modules, or media expansion modules. Fans, power supplies, and expansion modules are ordered separately to allow for building the system that meets your network needs.
Ruckus ICX 510 W DC PSU, power-supply-side intake (port-side exhaust) airflow ICX-FAN10-E Ruckus ICX 7450 power-supply-side exhaust airflow fan (two fans required with two power supplies) ICX-FAN10-I Ruckus ICX 7450 power-supply-side intake airflow fan (two fans required with two power supplies)
Page 15
Figure 2 shows the front view of the Ruckus ICX 7450-24P switch. NOTE PoE/PoE+ power is available to ports 1-24. High PoE/PoH is limited to ports 1-8. FIGURE 2 Front view of the Ruckus ICX 7450-24P System LEDs Mini-USB console port...
Page 16
Ruckus ICX 7450 Overview Views of the Ruckus ICX 7450 switch Figure 4 shows the front view of the Ruckus ICX 7450-48 switch. FIGURE 4 Front view of the Ruckus ICX 7450-48 System LEDs Mini-USB console port Media/Stacking module LEDs...
Figure 6 shows the front view of the Ruckus ICX 7450-48F switch. FIGURE 6 Front view of the Ruckus ICX 7450-48F System LEDs Mini-USB console port Media/Stacking module LEDs Reset button Stack unit ID display SFP port LEDs 1/1/1 - 1/1/48...
Page 18
• Slot 1 and Slot 2 are located on the front of the Ruckus ICX 7450-24 and ICX 7450-24P devices. Slot 1 contains 1 GbE RJ-45 ports 1/1/1 through 1/1/24, with odd port numbers on the top row and port 1/1/1 on the left. Slot 2 contains 1/10 GbE SFP+ ports 1/2/1 and 1/2/3 on the top row (left to right), and ports 1/2/2 and 1/2/4 on the bottom row (left to right).
• Slot 1 and Slot 2 are located on the front of the Ruckus ICX 7450-48F device. Slot 1 contains 1 GbE SFP ports 1/1/1 through 1/1/48, with odd port numbers on the top row and port 1/1/1 on the left. Slot 2 contains 1/10 GbE SFP+ ports 1/2/1 and 1/2/3 on the top row (left to right), and ports 1/2/2 and 1/2/4 on the bottom row (left to right).
QSFP+ 40GBase-SR-BD support The Ruckus ICX 7450 supports 40GBASE-SR-BD bi-directional (BiDi) QSFP+ transceivers with duplex LC optics. The 40 GbE BiDi optics support two 20 GbE channels over duplex fiber cable, with the transmit and receive of each channel operating at two wavelengths on a single fiber.
Page 22
Ruckus ICX 7450 Overview Supported transceivers and cables Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Shipping carton contents Ruckus ICX 7450 devices ship with all of the following items included in the shipping carton. When unpacking the device, verify that the contents of the shipping carton is complete, if any items are missing, contact the place of purchase.
• Because the Ruckus ICX 7450 can be ordered with fans that move air either front to back or back to front, be sure to orient your switch with the airflow pattern of any other devices in the rack. All equipment in the rack should force air in the same direction to avoid intake of exhaust air.
Keep LEDs visible by routing port cables and other cables away from the LEDs. Installation tasks Follow the steps listed in Table 6 to install your device. Details for each of these steps are provided on the pages indicated. Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Ensure that the physical environment that will host the device has the proper “Installation and safety considerations” on page 22 cabling and ventilation. If customizing a Ruckus ICX 7450 baseline chassis: “Installing and replacing a power supply unit” on page 56 Install at least one power supply unit.
For DC system, use grounding wire of at least 12 American Wire Gauge (AWG). The grounding wire should be attached to the DC input connector (as shown in Figure 52); the other end connects to the building ground. Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
VW-1, and rated minimum 90°C. Installing the device on a desktop Complete the following steps to install the Ruckus ICX 7450 on a desktop or other flat surface. FIGURE 14 Attaching the adhesive feet Attach the four adhesive feet to the bottom of the device.
Two-post rack, side view NOTE Use the following procedure when installing the Ruckus ICX 7450 in a two-post rack. For four-post racks, follow the procedures “Installing the 1U, 1.5U, and 2U Universal Kit for Four-Post Racks (XBR-R000295)” on page 29 or “Installing the Universal...
Page 30
Installing the Ruckus ICX 7450 Two-post rack mount installation FIGURE 16 Attaching the mounting brackets for a Ruckus ICX 7450 Position the device in the rack, providing temporary support under the switch until the rail kit is secured to the rack.
Use the screws specified in the procedure. Using longer screws can damage the device. Parts list The following parts are provided with the 1U, 1.5U, and 2U Universal Kit for Four-Post Racks Installation (XBR-R000295). Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
“Installing the device in the rack” on page 32 “Attaching the rear brackets to the extensions” on page 33 “Attaching the rear brackets to the rack posts” on page 34 Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 33
Repeat Step 1 and Step 2 to attach the left extension bracket to the left side of the device. Tighten all the 8-32 x 5/16-in. screws to a torque of 15 in-lb (17 cm-kg). Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 34
Attach the left front bracket to the left front rack post using two 10-32 x 5/8-in. panhead screws and two retainer nuts. Use the upper and lower holes in the bracket. Tighten all the 10-32 x 5/8-in. screws to a torque of 25 in-lb (29 cm-kg). Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 35
Repeat step 2 and step 3 to attach the left rear bracket to the left extension. Adjust the brackets to the rack depth and tighten all the 6-32 x 1/4-in. screws to a torque of 9 in-lb (10 cm-kg). Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 36
Attach the left rear bracket to the left rear rack post using two 10-32 x 5/8-in. panhead screws and two retainer nuts. Use the upper and lower holes in the bracket. Tighten all the 10-32 x 5/8-in. screws to a torque of 25 in-lb (29 cm-kg). Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
37 “Attaching the rear brackets to the extensions at the front of the device” on page 38 “Attaching the rear brackets to the front rack posts” on page 39 Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 38
Select the proper length extension bracket for your rack depth. Position the right extension along the side of the device as shown in Figure Attach the bracket using four 8-32 x 5/16-in. flathead screws. Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 39
Attach the left front bracket to the left rear rack post using two 10-32 x 5/8-in. panhead screws and two retainer nuts. Use the upper and lower holes in the bracket. Tighten all the 10-32 x 5/8-in. screws to a torque of 25 in-lb (29 cm-kg). Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 40
Repeat Step 2 and Step 3 to attach the left rear bracket to the left extension. Adjust the brackets to the rack depth and tighten all the 6-32 x 1/4-in. screws to a torque of 9 in-lb (10 cm-kg). Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 41
Attach the left rear bracket to the left front rack post using two 10-32 x 5/8-in. screws and two retainer nuts. Use the upper and lower holes in the bracket. Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Although this document describes how to install both single height (1U) and double height (2U) switches, the illustrations show a 1U switch as a typical installation. NOTE Hardware devices illustrated in these procedures are only for reference and may not depict the device you are installing into the rack. Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Allow 15 to 30 minutes to complete the installation. The following items are required to install the device using the Universal Four-Post Rack Kit: • #2 Phillips torque screwdriver • 1/4-inch slotted-blade torque screwdriver Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Use the screws specified in the procedure. Using longer screws can damage the device. Flush-front mounting CAUTION The device must be turned off and disconnected from the fabric during this procedure. Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 45
Complete the following steps to attach the extension brackets to the device. There are medium and long extension brackets that you can use for this step. Choose the correct extension bracket for the depth of your rack. Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 46
Attach the left front bracket to the left front rack post using two 10-32 x 5/8-in. panhead screws and two retainer nuts. Use the upper and lower holes in the bracket. Tighten all the 10-32 x 5/8-in. screws to a torque of 25 in-lb (29 cm-kg). Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 47
Adjust the brackets to the rack depth and tighten all the 6-32 x 1/4-in. screws to a torque of 9 in-lb (10 cm-kg). FIGURE 35 Attaching the rear brackets to the extensions Rear brackets Screws, 6-32 x 1/4-in., panhead Phillips Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
“Attaching the extensions to the front of the device” on page 47 “Installing the device in the rack” on page 48 “Attaching the rear brackets to the extensions at the front of the device” on page 49 Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 49
Repeat step 1 and step 2 to attach the left front extension to the left side of the device. Tighten all the 8-32 x 5/16-in. screws to a torque of 15 in-lb (17 cm-kg). Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 50
Attach the left front bracket to the left rear rack post using two 10-32 x 5/8-in. panhead screws and two retainer nuts. Use the upper and lower holes in the bracket. Tighten all the 10-32 x 5/8-in. screws to a torque of 25 in-lb (29 cm-kg). Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 51
Repeat step 2 and step 3 to attach the left rear bracket to the left extension. Adjust the brackets to the rack depth and tighten all the 6-32 x 1/4-in. screws to a torque of 9 in-lb (10 cm-kg). Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 52
Attach the left rear bracket to the left front rack post using two 10-32 x 5/8-in. screws and two retainer nuts. Use the upper and lower holes in the bracket. Tighten all the 10-32 x 5/8-in. screws to a torque of 25 in-lb (29 cm-kg). Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Connecting devices in a stack The Ruckus ICX 7450 can operate as a standalone device or as a member of a stack. A stack is a group of devices—Ruckus stackable units and their connected stacking links—that are connected so that the stack is managed as a single entity.
Stacking cables Use QSFP+ direct attached copper stacking cables or QSFP+ optics with fiber cables to connect the Ruckus ICX 7450 devices in a stack. The copper cable lengths for 40 GbE ports are 0.5 meter, 1 meter, 3 meters, or 5 meters.
Page 55
The following figures show linear and ring stacking using slot 2 on the front panel. Only the ICX7400-4X10GF module supports stacking using slot 2. Figure 47 shows a supported front panel linear stacking topology. FIGURE 47 Front panel linear stacking topology Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Grounding the system The rear panel of the Ruckus ICX 7450 includes a single-screw grounding terminal. The surface area around this terminal is not painted to provide a good electrical connection. Before connecting power to the device, the grounding terminal must be connected to ground to ensure proper operation and to meet electromagnetic interference (EMI) and safety requirements.
If the second power supply and second fan slot are unused, you must cover them with filler panels. NOTE Ruckus recommends that the Ruckus ICX 7450 switch operates with two power supplies and two fan trays installed. If a power supply or fan tray fails, it must be replaced as soon as possible.
For example, a Ruckus ICX 7450-24P has two power supplies installed. If you increase the maximum number of PoE ports that can be supported, and if the primary power supply fails, the redundant power supply cannot guarantee the device is protected by backup power.
When you are sure the power supply has properly engaged the connector, tighten the retainer screws to secure the power supply in the slot. When the Ruckus ICX 7450 is powered on, the LEDs on the power supply rear panel should light up green to confirm that the power supply is correctly installed and supplying power.
Page 60
Insert the DC power supply source wires into the DC wiring assembly, matching the terminals. Refer to Figure FIGURE 52 DC power supply wiring assembly Wire-tightening screws Earth ground wire DC power source wires Assembly screws Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
When you are sure the power supply has properly engaged the connector, tighten the chassis attachment screws to secure the power supply in the slot. When the Ruckus ICX 7450 is powered on, the power LED on the front of the device should turn green to confirm that the power supply is correctly installed and supplying power. Refer to “Ruckus ICX 7450 front-panel LEDs”...
The Gigabit Ethernet management port (RJ-45) on the Ruckus ICX 7450 front panel provides an out-of-band network connection to the device. After you assign an IP address, you can access the Ruckus ICX 7450 from anywhere in the attached network using Telnet, a web browser, or other network management tools, such as Ruckus Network Advisor.
For direct attachment from the device to a 1 GbE network interface card, switch, or router, using a fiber-optic transceiver, you will need fiber cabling with an LC connector. For information about transceivers supported on Ruckus ICX 7450 devices, refer to the Ruckus Optics Family Data Sheet.
Page 64
63. NOTE To verify that a Ruckus ICX 7450 can reach another device through the network, use the ping command at any level of the CLI. For more information, refer to the Ruckus FastIron Management Configuration Guide. Cleaning the fiber-optic connectors To avoid problems with the connection between the fiber-optic transceiver (SFP, SFP+, or QSFP+) and the fiber cable connectors, Ruckus strongly recommends cleaning both connectors each time you disconnect and reconnect them.
4x10 GbE mode of operation Figure 54 shows the LEDs on the Ruckus ICX 7450-24 front panel. The up-arrow port status LEDs for the 1 GbE ports correspond to the upper, odd-numbered ports; the down-arrow port status LEDs correspond to the lower, even-numbered ports.
Page 66
Module 3 and 4 are the right and left stacking modules on the rear panel, as viewed from the rear. The Ruckus ICX 7450-24P has the following LEDs on the front panel: • Two management port status LEDs (green) for speed and link/activity •...
Page 67
Figure 55 shows the LEDs on the Ruckus ICX 7450-24P front panel. The up-arrow port status LEDs for the 1 GbE ports correspond to the upper, odd-numbered ports; the down-arrow port status LEDs correspond to the lower, even-numbered ports. FIGURE 55 Ruckus ICX 7450-24P front-panel LEDs...
Page 68
Figure 56 shows the LEDs on the Ruckus ICX 7450-32ZP front panel. The up-arrow port status LEDs for the 1 GbE and 2.5 GbE ports correspond to the upper, odd-numbered ports; the down-arrow port status LEDs correspond to the lower, even-numbered ports.
Page 69
Figure 57 shows the LEDs on the Ruckus ICX 7450-48 front panel. The up-arrow port status LEDs for the 1 GbE ports correspond to the upper, odd-numbered ports; the down-arrow port status LEDs correspond to the lower, even-numbered ports.
Page 70
Figure 58 shows the LEDs on the Ruckus ICX 7450-48P front panel. The up-arrow port status LEDs for the 1 GbE ports correspond to the upper, odd-numbered ports; the down-arrow port status LEDs correspond to the lower, even-numbered ports.
Page 71
Figure 59 shows the LEDs on the Ruckus ICX 7450-48F front panel. The up-arrow port status LEDs for the 10 GbE ports correspond to the upper, odd-numbered ports; the down-arrow port status LEDs correspond to the lower, even-numbered ports.
Ruckus ICX 7450 Operation Ruckus ICX 7450 rear-panel LEDs Ruckus ICX 7450 rear-panel LEDs The Ruckus ICX 7450 has the following LEDs on the rear panel: • Expansion module power LED: One bicolor status LED (green and amber) • QSFP+ module LEDs: Four status LEDs (green) for the stacking port on the QSFP+ modules. Only the first LED is currently used, and indicates the status of the port in 40 GbE mode.
Page 73
Steady green Indicates stack unit identifier. (Unit numbers 11 and 12 are shown by No action required. using the 10+ LED in combination with the 1 or 2 LED.) Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 74
There is 10 GbE traffic and packets are being transmitted or received. No action required. Steady amber Link is up in 1 GbE mode. No action required. Blinking amber There is 1 GbE traffic and packets are being transmitted or received. No action required. Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
In offline diagnostics, you must turn the diagnostic flags on or off to execute diagnostic tests during the next bootup. The CLI commands for system diagnostic tests are dm diag and dm alt-diag. These diagnostic tests verify all available hardware components including: • I2C devices Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 76
System diagnostic testing runs at link speeds of 10 Gbps or 40 Gbps (for MOD2 QSFP+ data uplink ports) or 40 Gbps (for MOD3/MOD4 QSFP+ stacking ports) depending on the speed of the link being tested and the type of port. Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Replacing a fiber-optic transceiver You can remove an SFP, SFP+, or QSFP+ transceiver from a slot and replace it with a new one while the Ruckus ICX 7450 is powered on and running.
To clean the fiber cable connectors, Ruckus recommends using a fiber-optic reel-type cleaner. When not using an SFP, SFP+, or QSFP+ connector, make sure to keep the protective covering in place. Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
If a mismatched power source or fan tray is installed by mistake, a warning is sent to the console. The warning messages will be similar to the following: • For a fan mismatch: [WARNING, Ruckus ICX 7450, MISMATCH in Fan Air Flow direction. Replace FRU with fan air flows in the same direction. •...
CAUTION For the Ruckus ICX 7450 devices, be sure that the airflow direction of the power supply unit matches that of the installed fan tray. The power supplies and fan trays are clearly labeled with either a green arrow with an “E,” or an orange arrow with an “I.”...
The power supply will immediately attempt to power up. 11. Verify that the front-panel PSU LED for the new power supply displays steady green while the Ruckus ICX 7450 is operating. If the LED is not steady green, ensure that the power supply is securely installed and seated properly. For information about the...
Replacing an expansion module or service module The Ruckus ICX 7450 includes one front-panel slot and two rear-panel slots for media expansion or service modules, including a 4-port SFP 1 GbE module, a 4-port SFP+ 10 GbE module, a 4-port Copper 10 GbE module, or a 1-port QSFP+ 40 GbE module. The slots in...
Time and items required Replacing an expansion module or service module in the Ruckus ICX 7450 should take less than two minutes to complete. You need the following items to replace an expansion module or service module in the Ruckus ICX 7450: •...
Page 84
Managing the Ruckus ICX 7450 Replacing an expansion module or service module Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
ICX 7450-24: 24 1-GbE RJ-45 ports, four 10-GbE SFP+ uplink ports, two 40-GbE QSFP+ stacking ports, one power supply, and one fan unit ICX 7450-24P: 24 1-GbE RJ-45 ports (supporting PoE, PoE+, High PoE, PoH), four 10-GbE SFP+ uplink ports, two 40-GbE QSFP+ stacking ports, one power supply, and one fan unit ICX7450-32ZP: 24 1-GbE RJ-45 ports, 8 2.5-GbE RJ-45 ports (supporting PoE, PoE+, High PoE, PoH),...
Ruckus ICX 7450 Specifications Ethernet Ethernet These are standard modules for shipping bundles. For Ruckus ICX 7450 non-bundled switches, expansion modules need to be ordered separately. System component Description Maximum ports supported 40 GbE QSFP+ ports 1 40 GbE QSFP+ stacking or uplink port...
276 BTU/hr 1 x 510 W DC 100.1 W 99.2 W 85.3W 1 x 250 W AC 2 PSUs 342 BTU/hr 339 BTU/hr 291 BTU/hr 1 x 510 W DC Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
1 x 510 W DC 1402 W 1374 W 669.06 W 2 x 1000 W AC 2 PSUs required for PoE loading 4785 BTU/hr 4690 BTU/hr 2284 BTU/hr 2 x 510 W DC Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Maximum = 16.68 W ICX-FAN10-I Power-supply intake airflow fan (two fans required if two Typical = 4.68 W power supplies are used) Maximum = 16.68 W Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
MMF, 1000BASE-TX SFP Copper Serial port specifications (pinout - mini-USB) Signal Description Reserved Not used UART0_RX Debug port (data received by ICX) UART0_TX Console port (data transmitted by ICX) Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
• FCC Part 15, Subpart B (Class A) • EN 55022 (CE mark) (Class A) • EN 55024 (CE mark) (Immunity) for Information Technology Equipment • ICES-003 (Canada) (Class A) Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
30/2011/TT-BCT – Vietnam circular • SJ/T 11363-2006 Requirements for Concentration Limits for Certain Hazardous Substances in EIPs (China) • SJ/T 11364-2006 Marking for the Control of Pollution Caused by EIPs (China) Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Germany (Noise Warning) Maschinenlärminformations-Verordnung - 3. GPSGV, der höchste Schalldruckpegel beträgt 53.0 dB(A) gemäss EN ISO 7779. English translation of above statement Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Class A device (Broadcasting Communication Device for Office Use): This device obtained EMC registration for office use (Class A), and may be used in places other than home. Sellers and/or users need to take note of this. Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
English translation of above statement This is a Class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures. Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
English translation of above statement Warning: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 99
Note 3 The “−” indicates that the restricted substance corresponds to the exemption. : ICX7450-24-40G-E, ICX7450-24-E, ICX7450-24P-E-RMT3, ICX7450-24P, ICX7450-24P-E, ICX7450-24P-40G-E, ICX7450-24P-E2 : ICX7450-48-E, ICX7450-48P, ICX7450-48P-E, ICX7450-48P-E2, ICX7450-48P-E-RMT3, ICX7450-48P-STK-E, ICX7450-48P-STK-E-RMT3 : ICX7450-48F-E, ICX7450-48F-E-RMT3, ICX7450-48F-E2 Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
CAUTION All devices with DC power supplies (Ruckus ICX 7450) are intended for installation in restricted access areas only. A restricted access area is where access can be gained only by service personnel through the use of a special tool, lock and key, or other means of security, and is controlled by the authority responsible for the location.
Page 102
Ruckus ICX 7450 Cautions and Danger Notices Cautions CAUTION Use a separate branch circuit for each AC power cord, which provides redundancy in case one of the circuits fails. VORSICHT Es empfiehlt sich die Installation eines separaten Stromkreiszweiges für jede Wechselstrom-Elektroschnur als Redundanz im Fall des Ausfalls eines Stromkreises.
Page 103
CAUTION For the ICX 7450 devices, be sure that the airflow direction of the power supply unit matches that of the installed fan tray. The power supplies and fan trays are clearly labeled with either a green arrow with an “E,” or an orange arrow with an “I.”...
Page 104
CAUTION For the DC input circuit to the system of a Ruckus ICX 7450 make sure there is a 20 Amp circuit breaker, minimum 60 VDC, double pole, on the input lugs to the power supply. The input wiring for connection to the product should be Listed copper wire, 12 AWG, marked VW-1, and rated minimum 90°C.
Les procédures décrites dans ce manuel doivent être effectuées par le personnel de service qualifié uniquement. PELIGRO Los procedimientos de este manual se han hecho para personal de servicio cualificado. Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...
Page 106
Ruckus ICX 7450 Cautions and Danger Notices Danger notices DANGER Make sure the rack housing the device is adequately secured to prevent it from becoming unstable or falling over. GEFAHR Stellen Sie sicher, dass das Gestell die Unterbringung des Geräts auf angemessene Weise gesichert ist, so dass das Gestell nicht wackeln oder umfallen kann.
Page 107
Rayonnement de laser. Ne regardez pas directement avec les instruments optiques. Produits de laser de la classe 1M. PELIGRO Radiacion de Laser. No vea directamente con Instrumentos Opticos. Clase 1M de Productos de Laser. Ruckus ICX 7450 Switch Hardware Installation Guide Part Number: 53-1003899-07...