Ruckus Wireless Brocade FCX Series Hardware Installation Manual
Ruckus Wireless Brocade FCX Series Hardware Installation Manual

Ruckus Wireless Brocade FCX Series Hardware Installation Manual

Table of Contents

Advertisement

Quick Links

HARDWARE INSTALLATION GUIDE
Brocade FCX Series
Hardware Installation Guide
Part Number: 53-1003616-03
Publication Date: 15 June 2017

Advertisement

Table of Contents
loading

Summary of Contents for Ruckus Wireless Brocade FCX Series

  • Page 1 HARDWARE INSTALLATION GUIDE Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03 Publication Date: 15 June 2017...
  • Page 2 To find out which open source software is included in Brocade products, view the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support/oscd. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 3: Table Of Contents

    Attaching a PC or terminal..........................................48 Wiring map for serial cable........................................49 Installing and replacing a power supply unit....................................50 Installing or replacing fan trays.......................................... 50 Installing an optional module ..........................................52 Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 4 Power consumption (maximum configuration)...................................91 Data port specifications (Ethernet)........................................92 Serial port specifications (DB9).........................................93 Serial port specifications (pinout RJ-45).......................................93 Serial port specifications (protocol)........................................94 Regulatory compliance (EMC)........................................... 94 Regulatory compliance (safety)..........................................94 Regulatory compliance (environmental)......................................94 Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 5 VCCI statement..............................................101 Cautions and Danger Notices..................................... 103 Cautions................................................... 103 General cautions............................................103 Electrical cautions............................................105 Danger Notices..............................................106 General dangers............................................106 Electrical dangers............................................106 Dangers related to equipment weight....................................108 Laser dangers.............................................. 108 Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 6 Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 7: Preface

    Identifies keywords and operands. Identifies the names of GUI elements. Identifies text to enter in the GUI. italic text Identifies emphasis. Identifies variables. Identifies document titles. Identifies CLI output. Courier font Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 8: Command Syntax Conventions

    By sending your feedback to documentation@brocade.com Provide the publication title, part number, and as much detail as possible, including the topic heading and page number if applicable, as well as your suggestions for improvement. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 9: Contacting Brocade Technical Support

    Brocade Supplemental Support augments your existing OEM support contract, providing direct access to Brocade expertise. For more information, contact Brocade or your OEM. • For questions regarding service levels and response times, contact your OEM/solution provider. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 10 Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 11: About This Document

    What’s new in this document There are no enhancements in this edition. Supported Software For information about the features supported on a hardware platform, refer to the appropriate Features and Standards Support Matrix document. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 12 Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 13: Product Overview

    Two rear-panel power supply receptacles accommodate up to two power supply units that also support a rear-to-front cooling airflow. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 14 The following sections describe the physical characteristics of the FastIron CX models. For more details about physical dimensions, power supply specifications, and pinouts, refer to the "Brocade FCX Series Technical Specifications" section. The following figures show the front panels of the FastIron CX models. For more information about Combo ports, refer to...
  • Page 15 FIGURE 5 Brocade FCX 648S-HPOE front panel FIGURE 6 Brocade FCX 648S-HPOE rear panel FIGURE 7 Brocade FCX 624-E front panel FIGURE 8 Brocade FCX 624-I front panel FIGURE 9 Brocade FCX 648-E front panel Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 16: Control Features

    Brocade FCX 624-I and Brocade FCX 648-I Control features Each device front panel includes the following control features: • Serial management interface (the DB-9 port labeled Console ) • Out-of-band RJ-45 management Interface Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 17 FCX devices contain four combination ports, which are four Small Form Factor Pluggable (SFP) network interfaces (1F–4F) that are shared with four of the RJ-45 ports (ports 1–4). In the default configuration, if an SFP transceiver is installed in a slot and has a valid link Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 18 Slot locations There are three slot locations on Brocade FCX Series devices: slots 3 and 1 on the front panel and slot 2 on the rear panel. FIGURE 12 Slot locations on the front panel of Brocade FCX Series devices...
  • Page 19 The Brocade FCX 624S, FCX 648S, FCX 624S-F, FCX 624S-HPOE, and FCX 648S-HPOE devices include a slot on the front panel for a two-port 10 Gbps XFP uplink module. This module operates at 10 Gbps full duplex. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 20 FCX devices in a homogeneous stack, refer to the FastIron Ethernet Switch Stacking Configuration Guide. NOTE The 1 Gbps SFP and 10 Gbps SFP+ modules are not hot-swappable. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 21 The Up Link and Down Link LEDs on the front panel indicate operational status. If the Up Link or Down Link LED is on, the port is connected. If the Up Link or Down Link LED is off, no connection exists, or the link is down. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 22 Power on the member switch in the stack. In active/standby, reload the complete stack. NOTE There should not be any traffic injection until you reload the stack and the links are up again. Reconfigure the fixed LAGs. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 23 TABLE 6 10 Gbps SFP+ module port status LEDs Condition Status Link or Act LED (Link or Activity) On or flashing green Port has a valid link at 10 Gbps. Flashing indicates activity. The port is down. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 24 1/3/1 Port 1/3/1: Type : 10G XG-SR(SFP +) Vendor: Brocade Version: 1 Part# : PLRXPLSCS4371 Serial#: CXXXXXXXX device(config)# op 1 Enable optical monitoring and set alarm/warn interval to 1 minute(s) Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 25 This example shows how to specify port 2 in slot 2 of unit 3 in a stack: Brocade(config)# interface ethernet 3/2/2 Specifying a management port The management port number is always 1. This example shows how to specify the management port: Brocade(config)# interface management 1 Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 26 SFP(1F–4F) On Green The SFP port is operating at 1000 Mbps. On Amber The SFP port is operating at 100 Mbps. Speed A link is not established with a remote port. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 27 Up Link or Down Link (Stacking uplink or Green Uplink is operating normally. downlink port status) Uplink has failed or there is no link. Stack ID (1-8) Green Indicates the device stack ID. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 28 DC OK Green LEDs Off ‘DC OK’ LEDs Red AC OK Green Failure None and Off DC OK All ‘AC OK’ LEDs AC OK Power Off or None Failure DC OK Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 29 The SFP+ port has established a valid 10 Gbps link. Flashing indicates the port is transmitting Link or Activity and receiving user packets. A link is not established with a remote port. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 30 On/Flashing Green The port has established a valid link at 10/100/1000 Mbps. Flashing indicates the port is transmitting and receiving user packets. A link is not established with a remote port. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 31: Power Supplies

    The device has two power receptacles on the rear panel. Each device ships with one power supply installed. Brocade FCX 624S, FCX 648S, FCX 624S-F, FCX 624-E, FCX 624-I, FCX 648-E and FCX 648-I devices use a 210W PSU. Brocade FCX 624S-HPOE and Brocade FCX 648S-HPOE devices use a 620W PSU. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 32 Brocade FCX 624S-HPOE and Brocade FCX 648S-HPOE devices use a 620W PSU. When one PSU is powering the switch, the HPOE budget is 410W. If both PSUs are installed and powering the switch, each PSU provides 410W to the switch, increasing the HPOE budget to 820W. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 33: Installing The Fcx Switch

    Use the serial connection to perform basic configuration tasks, including assigning an IP address and network mask to the system. This information is required to manage the system using the Brocade Network Advisor or using the CLI through Telnet. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 34: Installation Tasks

    Follow all precautions when installing a Brocade device. General precautions DANGER All fiber-optic interfaces use Class 1 lasers. CAUTION Do not install the device in an environment where the operating ambient temperature might exceed 40°C (104°F). Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 35: Lifting Precautions

    Cabling infrastructure Ensure that the proper cabling is installed at the site. Refer to Cable specifications on page 66 or www.brocade.com for a summary of supported cabling types and their specifications. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 36: Installation Location

    You can install Brocade devices on a desktop or in an equipment rack. DANGER Make sure the rack housing the device is adequately secured to prevent it from becoming unstable or falling over. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 37: Desktop Installation

    Circuit overloading: Be sure that the supply circuit to the rack assembly is not overloaded. • Grounding: Rack-mounted equipment should be properly grounded. Particular attention should be given to supply connections other than direct connections to the mains. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 38 Preparing the installation site Use the following steps to mount devices in rack. Remove the rack mount kit from the shipping carton. The kit contains two L-shaped mounting brackets and mounting screws. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 39 FCX624-E, FCX624-I, FCX648-E, and FCX648-I device brackets are mounted using three screws. FIGURE 26 Attaching the brackets for the Brocade FCX 624S, FCX 648S, FCX 624S-F, FCX 624S-HPOE, and FCX 648S- HPOE devices Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 40 Preparing the installation site FIGURE 27 Attaching the brackets for the FCX624-E, FCX624-I, FCX648-E, and FCX648-I devices Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 41: Connecting Devices In A Traditional Stack

    Connecting devices in a traditional stack Brocade FCX Series devices can operate as standalone devices and also as members of traditional stacks. A stack is a group of devices--Brocade stackable units and their connected stacking links--that are connected so that the stack is managed as a single entity.
  • Page 42: Stacking Ports

    Stacking ports This section summarizes the default stacking ports and the ports that can be used as stacking ports on Brocade FCX Series devices. Default stacking ports have the capability to accept special stacking packets during a CLI-initiated command sequence of the Secure Setup utility.
  • Page 43: Stacking Configuration Requirements

    These FCX S/S-F modules 4-port 10 Gbps SFP+ module 2-port 10 Gbps XFP module NOTE Trunking is not supported on the Brocade FCX Series. Stacking configuration requirements • Before configuring the stack using the CLI, physically connect the devices using stacking cables.
  • Page 44: Stacking Cables

    For information about configuring a stack, refer to the FastIron Ethernet Switch Stacking Configuration Guide. Stacking cables To connect Brocade FCX Series devices in a stack, you need to use specific cables. TABLE 18 Cables used to connect Brocade FCX Series devices...
  • Page 45 Connecting devices in a traditional stack FIGURE 32 FCX S devices in linear (top) and ring (bottom) stacking topologies Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 46 Connecting devices in a traditional stack FIGURE 33 FCX E devices in a linear stacking topology FIGURE 34 FCX E devices in a ring stacking topology Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 47: Extended Distance Stacking

    After you complete the physical installation, you can power on the system. Remove the power cable from the shipping package. Attach the AC power cable to the AC connector on the rear panel. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 48: Attaching A Pc Or Terminal

    Connect a PC or terminal to the serial port of the system using a straight-through cable. The serial port has a male DB-9 connector. NOTE You need to run a terminal emulation program on the PC. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 49: Wiring Map For Serial Cable

    3 TXD (transmit data) 5 SGND (signal ground) <--------------------------> 5 SGND (signal ground) No other pins are used. NOTE As indicated in the table above, some of the wires should not be connected. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 50: Installing And Replacing A Power Supply Unit

    Ensure that the airflow direction of the power supply unit matches that of the installed fan tray. The power supplies and fan trays are clearly labeled with either a green arrow with an "E", or an orange arrow with an "I." Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 51 Before opening the package that contains the new fan tray, touch the bag to the switch casing to discharge any potential static electricity. It is recommended that you wear an ESD wrist strap during installation. Remove the fan tray from the anti-static shielded bag. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 52: Installing An Optional Module

    SFP+ module. The 10 Gbps SFP+ module allows you to use your device in a stack. On FCX624-E, FCX624-I, FCX648-E, and FCX648-I switches, optional SFP and SFP+ modules are not hot-swappable. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 53 Holding the module level, guide it into the carrier rails on each side and gently push it all the way into the slot, ensuring that it firmly engages with the connector. When you are sure the module has properly engaged the connector, tighten the retainer screws to secure the module in the slot. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 54: Optional 2-Port 10 Gbps Sfp+ Uplink Module

    Power on the member switch in the stack. In active/standby, reload the complete stack. NOTE There should not be any traffic injection until you reload the stack and the links are up again. Reconfigure the fixed LAGs. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 55 TABLE 20 10 Gbps SFP+ module port status LEDs Condition Status Link or Act LED (Link or Activity) On or flashing green Port has a valid link at 10 Gbps. Flashing indicates activity. The port is down. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 56 1/3/1 Port 1/3/1: Type : 10G XG-SR(SFP +) Vendor: Brocade Version: 1 Part# : PLRXPLSCS4371 Serial#: CXXXXXXXX device(config)# op 1 Enable optical monitoring and set alarm/warn interval to 1 minute(s) Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 57 1/1/22:C 1/1/23:C 1/1/24:C 1/1/25:C 1/1/26:C 1/1/27:C 1/1/28:C 1/1/29:C 1/1/30:C 1/1/31:C 1/1/32:C 1/1/33:C 1/1/34:C 1/1/35:C 1/1/36:C 1/1/37:C 1/1/38:C 1/1/39:C 1/1/40:C 1/1/41:C 1/1/42:C 1/1/43:C 1/1/44:C 1/1/45:C 1/1/46:C 1/1/47:C 1/1/48:C 1/2/1:XG-CX4 1/2/2:XG-CX4 1/3/1:XG-ER 1/3/2:XG-USR Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 58 Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 59: Checking Network Devices And Testing Connectivity

    Read Only - Allows access to the Privileged EXEC mode and CONFIG mode but only with read access. Setting passwords At the opening CLI prompt, enter the following command to change to the Privileged level of the EXEC mode: device> enable Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 60: Recovering From A Lost Password

    Routing (CIDR) network prefix masks. • To enter a classical network mask, enter the mask in IP address format. For example, enter "10.157.22.99 255.255.255.0" for an IP address with a Class-C subnet mask. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 61: Devices Running Layer 2 Software

    You do not need to assign a default gateway address for single subnet networks. Syntax: enable [ password ] Syntax: configure terminal Syntax: [no] ip address ip-addr ip-mask Syntax: [no] ip address ip-addr/mask-bits Syntax: ip default-gateway ip-addr Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 62: Devices Running Layer 3 Software

    Use the secondary parameter if you have already configured an IP address within the same subnet on the interface. Configuring IP parameters for devices running Layer 3 software This section describes how to configure IP parameters for devices running Layer 3 software. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 63 If you configure the Brocade switch to use a loopback interface to communicate with a BGP4 neighbor, you must also configure a loopback interface on the neighbor and configure the neighbor to use that loopback interface to communicate with theBrocade switch. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 64 This command deletes IP address 10.1.2.1. You do not need to enter the subnet mask. To delete all IP addresses from an interface, enter the following command: device(config-if-1/1/1)# no ip address * Syntax: [no] ip address ip-addr | * Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 65: Performing A Factory Reset

    Before plugging a cable into to any port, be sure to discharge the voltage stored on the cable by touching the electrical contacts to ground surface. Refer to “Cable specifications” for cable lengths and types. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 66: Cable Specifications

    For copper connections to Ethernet hubs, a 10/100BaseTX or 1000BaseT switch, or another Brocade device, a crossover cable is required. If the hub is equipped with an uplink port, it will require a straight-through cable instead of a crossover cable. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 67 1000Base-T ports. In this case a straight-through cable may work just as well as a crossover cable. For more information about this feature, refer to the FastIron Ethernet Switch Security Configuration Guide. FIGURE 43 UTP crossover cable FIGURE 44 Straight-through cable Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 68: Connecting To Workstations, Servers, Or Routers

    You can install a new transceiver in an XFP, SFP, or SFP+ slot while the device is powered on and running. While installing a transceiver, wear an ESD wrist strap with a plug for connection to a metal surface. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 69 Put on the ESD wrist strap and ground yourself by attaching the clip end to a metal surface (such as an equipment rack) to act as ground. Remove the new transceiver from the protective packaging. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 70 Gently insert the transceiver into the slot until it clicks into place. Transceivers are keyed to prevent incorrect insertion. FIGURE 45 Installing a transceiver into FCX-624S, FCX-648S, FCX-624S, FCX-624S-HPOE, and FCX-648S-HPOE devices Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 71 To avoid problems with the connection between the fiber optic transceiver (SFP, SFP+, or mini-GBIC) and the fiber cable connectors, Brocade strongly recommends cleaning both connectors each time you disconnect and reconnect them. Dust can accumulate in the connectors and cause problems such as reducing the optic launch power. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 72: Testing Connectivity

    • Verify that the port has not been disabled through a configuration change. You can use the CLI. If Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 73 • Verify that the transmit port on the Brocade device is connected to the receive port on the other network Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 74 You can do Speed the following: • Check the Link LED to make sure the link is still established with the remote port. If not, take the actions described Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 75 For information about cleaning the connectors, refer Cleaning the fiber-optic connectors page 71. • Verify that the port has not been disabled through Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 76: Tracing A Route

    Verify that the device and the connected device are both powered on and operating correctly. • Verify that you have used the correct cable type for the connection: – For twisted-pair connections to an end node, use straight-through cabling. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 77: Digital Optical Monitoring

    To diagnose a cable using TDR, enter commands such as the following at the Privileged EXEC level of the CLI. device# phy cable-diagnostics tdr 1/1/1 The clear-diag tdr command clears results of any previous TDR test from test registers for port 1/1/1 (port 1 on slot 1 on device 1). Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 78 T568A pair and color assignment Pair A Pair 3 (green) Pair B Pair 2 (orange) Pair C Pair 1 (blue) Pair D Pair 4 (brown) The following figure illustrates the T568A pin/pair assignment. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 79 Terminated: The link is up. • Shorted: A short is detected in the cable. • Open: An opening is detected in the cable. • ImpedMis: The impedance is mismatched. • Failed: The TDR test failed. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 80 Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 81: Managing The Fcx Hardware

    2 <- 3 @ 62 deg-C MAC 1 Temperature Readings: Current temperature : 58.5 deg-C CPU Temperature Readings: Current temperature : 52.0 deg-C Warning level..: 75.0 deg-C Shutdown level..: 90.0 deg-C Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 82 Power supply 2 not present Fan ok, speed (auto): [[1]]<->2<->3 Fan speed switching temperature thresholds: 1 -> 2 @ 61 deg-C 1 <- 2 @ 56 deg-C 2 -> 3 @ 67 deg-C Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 83 Enter a command to the following to change the temperature shutdown level from 80 deg-C to 90 deg-C. device# stack unit 1 device(config-unit-1)# fan-threshold mp speed-3 50 90 Syntax: fan-threshold mp speed-3 lowest-value highest-value Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 84: Removing Mac Address Entries

    Use the mac-address parameter to remove a specified MAC address from all VLANs. Specify the MAC address in the following format: HHHH.HHHH.HHHH. Use the ethernet port-num parameter to remove all MAC addresses for a specified Ethernet port. Use the vlan number parameter to remove all MAC addresses for a specified VLAN. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 85: Displaying Fcx Cpu Usage

    Put on the ESD wrist strap and ground yourself by attaching the clip end to a metal surface (such as an equipment rack). Disconnect the copper or fiber cable connector from the port connector. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 86: Cabling A Fiber Optic Module

    Install a new copper or fiber optic module in the port. Cabling a fiber optic module For instructions on cabling a fiber optic module refer to Cabling a fiber-optic transceiver on page 71. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 87: Cleaning The Fiber Optic Connectors

    Replacing a copper or fiber optic module Cleaning the fiber optic connectors For instructions on cleaning a fiber optic module refer to Cleaning the fiber-optic connectors on page 71. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 88 Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 89: Brocade Fcx Series Technical Specifications

    Brocade FCX Series Technical Specifications This document highlights the features and specifications for the Brocade FCX Series switches. System specifications System component Description Enclosure 1U, 19-inch EIA-compliant, power from non-port side Power inlet Power supplies Up to two internal, redundant, field-replaceable, load-sharing AC power supplies...
  • Page 90: Other

    17.32 in 17.13 in 12.59 lbs Environmental requirements Condition Operational Non-operational Ambient temperature 32°F to 104°F −25°C to 70°C (−23°F to 158°F) 0°C to 40°C Relative humidity (non- 5% to 95% condensing) Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 91: Power Supply Specifications (Per Psu)

    0.6 A With 4-port 10 GbE module installed and 92 W one power supply. FCX 648 1.2 A 0.7 A With 4-port 10 GbE module installed and 112 W one power supply. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 92: Data Port Specifications (Ethernet)

    2 SFP+ or 2 Supports maximum two SFP+ or two XFP 10 Gigabit Ethernet ports per system. XFP (optional) 16 Gbps CX4 Supports maximum two 16 Gbps CX4 stacking ports per system. stacking ports Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 93: Serial Port Specifications (Db9)

    Receive data Reserved Reserved Logic ground Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Serial port specifications (pinout RJ-45) Signal Description Not supported Not supported UART1_TXD Transmit data Logic ground Logic ground Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 94: Serial Port Specifications (Protocol)

    2012/19/EU - Waste electrical and electronic equipment (EU WEEE) • 94/62/EC - packaging and packaging waste (EU) • 2006/66/EC - batteries and accumulators and waste batteries and accumulators (EU battery directive) Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 95 30/2011/TT-BCT - Vietnam circular • SJ/T 11363-2006 Requirements for Concentration Limits for Certain Hazardous Substances in EIPs (China) • SJ/T 11364-2006 Marking for the Control of Pollution Caused by EIPs (China) Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 96 Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 97: Troubleshooting

    IP address. Also, be sure the port through which you are connecting to the switch has not been disabled. If it has not been disabled, then check the network cabling that runs between your remote location and the switch. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 98 Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 99: Regulatory Statements

    BSMI statement (Taiwan) Warning: This is Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 100: Canadian Requirements

    This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations, ICES-003 Class A. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. China CC statement Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 101: Europe And Australia (Cispr 22 Class A Warning)

    This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance might arise. When such trouble occurs, the user might be required to take corrective actions. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 102 Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 103: Cautions And Danger Notices

    Si usted borra accidentalmente la configuración en un sistema ya configurado, introduzca el comando write memory (escribir memoria) para guardar la configuración en ejecución en el archivo startup-config. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 104 8 cm sur chaque côté. PRECAUCIÓN Asegúrese de proporcionar una ventilación adecuada al sistema. Se recomienda dejar 3 cm de espacio libre por encima del dispositivo y 8 cm a cada lado. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 105: Electrical Cautions

    Si vous n’installez pas de module ou de bloc d'alimentation dans un slot, vous devez laisser le panneau du slot en place. Si vous faites fonctionner le châssis avec un slot découvert, le système surchauffera. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 106: Danger Notices

    Débranchez le cordon d'alimentation de toutes les sources d'alimentation pour couper complètement l'alimentation du dispositif. PELIGRO Para desconectar completamente la corriente del instrumento, desconecte el cordón de corriente de todas las fuentes de corriente. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 107 Das eingeschaltete Gerät darf nicht geöffnet werden, da andernfalls das Risiko eines Stromschlags mit Hochspannung besteht. DANGER Afin d'éviter tout choc électrique, n'ouvrez pas l'appareil lorsqu'il est sous tension. PELIGRO Para evitar una descarga de alto voltaje, no abra el dispositivo mientras esté encendido. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...
  • Page 108: Dangers Related To Equipment Weight

    Alle Glasfaser-Schnittstellen verwenden Laser der Klasse 1. DANGER Toutes les interfaces en fibres optiques utilisent des lasers de classe 1. PELIGRO Todas las interfaces de fibra óptica utilizan láser de clase 1. Brocade FCX Series Hardware Installation Guide Part Number: 53-1003616-03...

Table of Contents