Table of Contents

Advertisement

Quick Links

HARDWARE INSTALLATION GUIDE
RUCKUS ICX 8200 Switch
Hardware Installation Guide
Part Number: 53-1005735-01
Publication Date: 15 December 2022

Advertisement

Table of Contents
loading

Summary of Contents for Ruckus Wireless ICX 8200

  • Page 1 HARDWARE INSTALLATION GUIDE RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01 Publication Date: 15 December 2022...
  • Page 2 Trademarks ARRIS, the ARRIS logo, COMMSCOPE, RUCKUS, RUCKUS WIRELESS, the Ruckus logo, the Big Dog design, BEAMFLEX, CHANNELFLY, FASTIRON, ICX, SMARTCELL and UNLEASHED are trademarks of CommScope, Inc. and/or its affiliates. Wi-Fi Alliance, Wi-Fi, the Wi-Fi logo, Wi-Fi Certified, the Wi-Fi CERTIFIED logo, Wi-Fi Protected Access, the Wi-Fi Protected Setup logo, Wi-Fi Protected Setup, Wi-Fi Multimedia and WPA2 and WMM are trademarks or registered trademarks of Wi-Fi Alliance.
  • Page 3: Table Of Contents

    Time and Items Required....................32 RUCKUS ICX 8200 Switch Hardware Installation Guide...
  • Page 4 LED Activity Interpretation....................71 RUCKUS ICX 8200 Switch Hardware Installation Guide...
  • Page 5 Korea ........................98 RUCKUS ICX 8200 Switch Hardware Installation Guide...
  • Page 6 Danger Notices ......................107 RUCKUS ICX 8200 Switch Hardware Installation Guide...
  • Page 7: Preface

    Worldwide toll number for our support organization. Phone charges will apply: +1-650-265-0903 We suggest that you keep a physical note of the appropriate support number in case you have an entire network outage. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 8: Self-Service Resources

    RUCKUS Training Portal at https://commscopeuniversity.myabsorb.com/. The registration is a two-step process described in this video. You create a CommScope account and then register for, and request access for, CommScope University. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 9: Document Conventions

    Repeat the previous element, for example, member[member...]. Indicates a “soft” line break in command examples. If a backslash separates two lines of a command input, enter the entire command at the prompt without the backslash. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 10 Preface Command Syntax Conventions RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 11: About This Document

    Supported Hardware and Software ............... . 11 Supported Hardware and Software This document is applicable for the various RUCKUS ICX 8200 switch models. The following tables list the device models, power supplies, fan assemblies, and rack mount kits supported.
  • Page 12 1U, 1.5U, and 2U Universal Kit for Four-Post Racks Not included with the device. Optionally orderable. ICX7000-RMK Two-post fixed rack mount kit Included with ICX 8200 24-port and 48-port models. ICX7000-C12-RMK Compact switch mount kit Not included with the device. Optionally orderable.
  • Page 13: Device Overview

    Hardware Features The RUCKUS ICX 8200 is a high-density enterprise access switch that offers 10, 100, and 1000 Mbps and 1, 10, and 25 Gigabit Ethernet (GbE) line rates, low latency store-and-forward switching, and up to 296 Gbps throughput for campus LAN environments.
  • Page 14: Port-Side Views Of The Ruckus Icx 8200 Switch

    Port-Side Views of the RUCKUS ICX 8200 Switch Port-Side Views of the RUCKUS ICX 8200 Switch Figure 1 shows the front view of the RUCKUS ICX 8200-48 switch. FIGURE 1 Front View of the RUCKUS ICX 8200-48 USB port (for external disk drive)
  • Page 15 Status mode button and LEDs Slot 2: 1/10/25 GbE SFP28 stacking/uplink ports Figure 4 shows the front view of the RUCKUS ICX 8200-48PF2 switch. FIGURE 4 Front View of the RUCKUS ICX 8200-48PF2 USB port (for external disk drive) Reset button...
  • Page 16 USB Type-C console port Slot 2: 1/10/25 GbE SFP28 stacking/uplink ports Figure 6 shows the front view of the RUCKUS ICX 8200-24P switch. FIGURE 6 Front View of the RUCKUS ICX 8200-24P USB port (for external disk drive) Management port (RJ-45)
  • Page 17: Nonport-Side View Of The Ruckus Icx 8200 Switch

    Slot 2: 1/10 Gbps SFP+ stacking/uplink ports Nonport-Side View of the RUCKUS ICX 8200 Switch Figure 8 shows the rear view of the RUCKUS ICX 8200-48 switch. FIGURE 8 Rear View of the RUCKUS ICX 8200-48 Fan vent AC power socket Figure 9 shows the rear view of the RUCKUS ICX 8200-48P switch.
  • Page 18 FIGURE 10 Rear View of the RUCKUS ICX 8200-48PF Fan vents AC power socket Figure 11 shows the rear view of the RUCKUS ICX 8200-48PF2 switch. FIGURE 11 Rear View of the RUCKUS ICX 8200-48PF2 Fan assembly 2 Power supply unit 2...
  • Page 19: Device Management Options

    FIGURE 13 Rear View of the RUCKUS ICX 8200-24P Fan vents AC power socket Figure 14 shows the rear view of the RUCKUS ICX 8200-C08PF switch. FIGURE 14 Rear View of the RUCKUS ICX 8200-C08PF AC power socket Kensington lock slot...
  • Page 20 Device Overview Device Management Options RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 21: Preparing For Installation

    Make sure the airflow around the front, sides, and back of the device is not restricted. CAUTION To protect the serial port from damage, keep the cover on the port when not in use. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 22: Esd Precautions

    Disconnect the power cord from all power sources to completely remove power from the device. DANGER This device might have more than one power cord. To reduce the risk of electric shock, disconnect all power cords before servicing. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 23: Lifting Precautions

    21 CFR Subchapter I, and with IEC 60825 and EN60825. Optical products that do not comply with these standards might emit light that is hazardous to the eyes. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 24: Facility Requirements

    • Airflow and temperature requirements are met on an continual basis, particularly if the device is installed in a closed or multirack assembly. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 25: Recommendations For Cable Management

    For easier maintenance, label the cables and record the devices to which they are connected. • Keep LEDs visible by routing port cables and other cables away from the LEDs. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 26: Quick Installation Checklist

    Ensure that the physical environment that will host the device has “Facility Requirements” on page 24 the proper cabling and ventilation. If customizing a RUCKUS ICX 8200-48PF2 switch baseline chassis: “Inserting a New AC Power Supply” on page 82 Install at least one power supply unit.
  • Page 27: Shipping Carton Contents

    Shipping Carton Contents RUCKUS ICX 8200 devices ship with all of the following items included in the shipping carton. When unpacking the device, verify that the contents of the shipping carton are complete. If any items are missing, contact the place of purchase.
  • Page 28 Preparing for Installation Shipping Carton Contents RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 29: Mounting The Device

    Connecting Devices in a Stack................57 Mounting Options The RUCKUS ICX 8200 24-port and 48-port switches support the following mounting options: •...
  • Page 30: Precautions Specific To Mounting

    Use the screws specified in the procedure. Using longer screws can damage the device. CAUTION Do not install the device in an environment where the operating ambient temperature might exceed 45°C (113°F). RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 31: Mounting On A Desktop Or Flat Surface

    Mounting on a Desktop or Flat Surface Mounting on a Desktop or Flat Surface Complete the following steps to install the RUCKUS ICX 8200 24-port and 48-port switches on a desktop or other flat surface. FIGURE 15 Installing on a Flat Surface Set the device on a flat desktop, table, or shelf near an AC power source.
  • Page 32: Mounting A 24-Port Or 48-Port Switch On A Wall

    If installing multiple devices, attach the adhesive feet to each device. Place each device squarely on top of the one below. Mounting a 24-Port or 48-Port Switch on a Wall Use the following instructions to install a RUCKUS ICX 8200 24-port or 48-port switch on a wall using the two-post rack mount brackets included with the switch.
  • Page 33 Attach the left front bracket to the wall using two 4x25-mm panhead screws. Use the upper and lower holes in the bracket. Tighten all the 4x25-mm screws to a torque of 25 in-lb (29 cm-kg). RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 34: Mounting A Compact Switch On A Wall

    Screws, 4x25-mm panhead Phillips Wall-mount anchors Mounting a Compact Switch on a Wall Use the following instructions to install a RUCKUS ICX 8200 compact switch on a wall using the wall-mount anchors and screws included with the switch. Time and Items Required Allow 15 to 30 minutes to complete the installation.
  • Page 35: Mounting A Compact Switch Under A Flat Surface Or On A Ceiling

    Mounting a Compact Switch Under a Flat Surface or on a Ceiling Use the following instructions to install a RUCKUS ICX 8200 compact switch under a flat surface or on a ceiling using the compact switch mount kit (ICX7000-C12-RMK). Time and Items Required Allow 15 to 30 minutes to complete the installation.
  • Page 36: Installing The Device Under A Flat Surface Or On A Ceiling

    Figure 20 Figure Tighten all M4x8 screws to a torque of 15 in-lb (17 cm-kg). FIGURE 20 Attaching the Long Front Brackets for Ceiling Mounting Front brackets Screws, M4x8, panhead Phillips RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 37 Tighten the screws to a torque of 25 in-lb (29 cm-kg). FIGURE 22 Positioning the Device Under a Flat Surface or on a Ceiling Wall-mount anchors Screws, 4x25-mm, panhead Phillips RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 38: Mounting A Compact Switch On A Din Rail

    Mounting a Compact Switch on a DIN Rail Mounting a Compact Switch on a DIN Rail Use the following instructions to install the RUCKUS ICX 8200-C08PF compact switch on a 35-mm, 7.5-mm deep, top hat section, type O DIN rail using the DIN rail mounting kit (ICX-DIN-MNT).
  • Page 39 Push the lower edge of the mounting plate onto the DIN rail until it latches securely to the rail. NOTE Pull the release tab down to remove the device from the DIN rail. FIGURE 24 Mounting the Device on a DIN Rail DIN rail Release tab RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 40: Mounting A 24-Port Or 48-Port Switch In A Two-Post Rack

    “Installing the 1U, 1.5U, and 2U Universal Kit for Four-Post Racks (XBR-R000295)” on page 46. Use the following instructions to install the RUCKUS ICX 8200 switch in two-post Telco racks using the two-post rack mount brackets included with the switch.
  • Page 41: Parts List

    Repeat Step 1 and Step 2 to attach the left front bracket to the left side of the device. Tighten all 6-32 x 5/16-in. screws to a torque of 15 in-lb (17 cm-kg). RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 42 Attach the left front bracket to the left front rack post using two 10-32 x 5/8-in. panhead screws and two retainer nuts. Use the upper and lower holes in the bracket. Tighten all the 10-32 x 5/8-in. screws to a torque of 25 in-lb (29 cm-kg). RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 43: Mounting A Compact Switch In A Two-Post Rack

    Screws, 10-32 x 5/8-in., panhead Phillips Mounting a Compact Switch in a Two-Post Rack Use the following instructions to install a RUCKUS ICX 8200 compact switch in a two-post Telco rack using the compact switch mount kit (ICX7000-C12-RMK). Time and Items Required Allow 15 to 30 minutes to complete the installation.
  • Page 44: Parts List

    Repeat Step 1 and Step 2 to attach the left front bracket to the left side of the device. Tighten all M4x8 screws to a torque of 15 in-lb (17 cm-kg). RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 45 Tighten all the 10-32 x 5/8-in. screws to a torque of 25 in-lb (29 cm-kg). FIGURE 31 Positioning the Device in the Rack Screws, 10-32 x 5/8-in., panhead Phillips Retainer nuts, 10-32 RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 46: Installing The 1U, 1.5U, And 2U Universal Kit For Four-Post Racks (Xbr-R000295)

    Installing the 1U, 1.5U, and 2U Universal Kit for Four-Post Racks (XBR-R000295) Use the following instructions to install a RUCKUS ICX 8200 switch in a 19-in. (48.3 cm) EIA rack using the 1U, 1.5U, and 2U Universal Kit for Four-Post Racks (XBR-R000295).
  • Page 47: Flush-Front Mounting The Device In The Rack

    51 Attaching the Front Brackets Complete the following steps to attach the two-post rack mount brackets included with the RUCKUS ICX 8200 switch to the front of the device. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 48 Repeat Step 1 and Step 2 to attach the left bracket extension to the left side of the device. Tighten all the 8-32 x 5/16-in. screws to a torque of 15 in-lb (17 cm-kg). RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 49 Attach the left front bracket to the left front rack post using two 10-32 x 5/8-in. panhead screws and two retainer nuts. Use the upper and lower holes in the bracket. Tighten all the 10-32 x 5/8-in. screws to a torque of 25 in-lb (29 cm-kg). RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 50 Repeat Step 1 and Step 2 to attach the left rear bracket to the left bracket extension. Adjust the brackets to the rack depth and tighten all the 6-32 x 1/4-in. screws to a torque of 9 in-lb (10 cm-kg). RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 51 Attach the left rear bracket to the left rear rack post using two 10-32 x 5/8-in. panhead screws and two retainer nuts. Use the upper and lower holes in the bracket. Tighten all the 10-32 x 5/8-in. screws to a torque of 25 in-lb (29 cm-kg). RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 52: Flush-Rear (Recessed) Mounting The Device In The Rack

    54 “Attaching the Rear Brackets to the Bracket Extensions at the Front of the Device” on page 55 “Attaching the Rear Brackets to the Front Rack Posts” on page 56 RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 53 Figure Attach the bracket using four 6-32 x 5/16-in. flathead screws. Repeat Step 1 and Step 2 to attach the left bracket extension to the left side of the device. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 54 Attach the left front bracket to the left rear rack post using two 10-32 x 5/8-in. panhead screws and two retainer nuts. Use the upper and lower holes in the bracket. Tighten all the 10-32 x 5/8-in. screws to a torque of 25 in-lb (29 cm-kg). RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 55 Repeat Step 1 and Step 2 to attach the left rear bracket to the left bracket extension. Adjust the brackets to the rack depth and tighten all the 6-32 x 1/4-in. screws to a torque of 9 in-lb (10 cm-kg). RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 56 Screws, 6-32 x 1/4-in., panhead Phillips Rear bracket, medium or long Attaching the Rear Brackets to the Front Rack Posts Complete the following steps to attach the rear brackets to the front rack posts. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 57: Connecting Devices In A Stack

    Stacking Ports There are four 25-GbE SFP28 ports on the front panel of the RUCKUS ICX 8200 24-port and 48-port switches that can be used as stacking ports. The RUCKUS ICX 8200-C08PF switch has two 10-GbE SFP+ stacking ports on the front panel. The stacking ports can also be configured as uplink (data) ports.
  • Page 58: Stacking Configuration Requirements

    The 25-GbE ports 1/2/1 and 1/2/3 are default stacking ports (supporting 10-GbE and 25-GbE stacking). Default stacking ports have the capability to accept special stacking packets during a CLI-initiated command sequence of the Secure Setup utility. The following figure shows the stacking ports on the RUCKUS ICX 8200-C08PF. FIGURE 46 RUCKUS ICX 8200-C08PF Stacking Ports The 10-GbE ports 1/2/1 and 1/2/2 are default stacking ports (supporting only 10-GbE stacking).
  • Page 59: Stacking Cables

    Mounting the Device Connecting Devices in a Stack Stacking Cables Use SFP28 or SFP+ direct-attached copper stacking cables or SFP28 or SFP+ optics with fiber cables to connect the RUCKUS ICX 8200 devices in a stack. NOTE Stacking cables are not included in the shipping carton and must be ordered separately.
  • Page 60: Interactive-Setup Utility

    1 connects to unit 2, unit 2 connects to unit 3, and unit 3 connects to unit 1. Figure 49 shows a supported ring stacking topology using the 25-GbE stacking ports on RUCKUS ICX 8200-48 switches. FIGURE 49 25-GbE Ring Stacking Topology...
  • Page 61: Zero-Touch Provisioning

    In a ring of more than two units, all directions of any unit are fully utilized because each direction is to a different unit. Therefore, the linear-topology trunk is not supported in a stack of more than two units. FIGURE 50 RUCKUS ICX 8200-48 Two-Unit Stack with Linear-Topology Trunk (Four Ports) NOTE For more information about stacking, refer to the RUCKUS FastIron Stacking Configuration Guide.
  • Page 62 Mounting the Device Connecting Devices in a Stack RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 63: Initial Setup And Verification

    Establishing an Out-of-Band Management Port Connection ........... . 64 Providing Power to the Device After you complete the physical installation, you can power on the system. Install alternating-current (AC) power supplies in the RUCKUS ICX 8200-48PF2 switch. Refer to “Power Supplies” on page 81. The RUCKUS ICX 8200-48PF2 is the only model that takes an installable power supply.
  • Page 64: Establishing An Out-Of-Band Management Port Connection

    Establishing an Out-of-Band Management Port Connection Connect the serial cable to the RJ-45 or USB Type-C console port on the front of the RUCKUS ICX 8200 switch and to an RS-232 serial port on the workstation using the RJ-45-to-DB9 adapter included in the shipping carton or a USB Type-C serial console port cable.
  • Page 65: Installing Transceivers And Cables

    Cables can be organized and managed in a variety of ways, for example, using cable channels on the sides of the rack or patch panels to minimize cable management. Follow these recommendations: RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 66: Installing A Fiber-Optic Transceiver

    For safety reasons, the ESD wrist strap should contain a series 1 megohm resistor. DANGER Laser radiation. Do not view directly with optical instruments. Class 1M laser products. Use the following steps to install a transceiver. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 67: Replacing A Fiber-Optic Transceiver

    Replacing a Fiber-Optic Transceiver You can remove a fiber-optic transceiver from a slot and replace it with a new one while the RUCKUS ICX 8200 switch is powered on and running. While removing a fiber-optic transceiver, be sure to wear an ESD wrist strap that is connected to ground.
  • Page 68: Connecting Network Devices

    For direct attachment from the device to a network interface card, switch, or router, using a fiber-optic transceiver, you will need fiber cabling with an LC connector. For information about transceivers supported on the RUCKUS ICX 8200 switch, refer to the RUCKUS Optics Family Data Sheet.
  • Page 69 71. NOTE To verify that a RUCKUS ICX 8200 switch can reach another device through the network, use the ping command at any level of the CLI. For more information, refer to the RUCKUS FastIron Management Configuration Guide.
  • Page 70 Installing Transceivers and Cables Connecting Network Devices RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 71: Monitoring The Device

    Two management port status LEDs (green) for link/activity (LINK/ACT) and speed (SPD) • One or two power supply unit (PSU) bicolor status LEDs (green and amber) labeled PWR and PWR2 (PWR2 is only on the ICX 8200-48PF2) • One SYS (system) bicolor status LED (green and amber) •...
  • Page 72: Ruckus Icx 8200 Nonport-Side Leds

    SFP+ port link/activity LEDs RUCKUS ICX 8200 Nonport-Side LEDs The RUCKUS ICX 8200-48PF2 has two bicolor power supply status LEDs (green and red) on each installed power supply. Figure 54 shows the LEDs on the rear panel of the RUCKUS ICX 8200-48PF2.
  • Page 73: Status Mode Button And Leds

    Monitoring the Device Status Mode Button and LEDs FIGURE 54 RUCKUS ICX 8200-48PF2 Rear-Panel LEDs Power supply unit 1 DC LED Power supply unit 2 DC LED Power supply unit 1 AC LED Power supply unit 2 AC LED Status Mode Button and LEDs The status mode button is used to select the corresponding status indicated by the port status LEDs.
  • Page 74: Led Patterns

    Monitoring the Device LED Patterns LED Patterns The following tables describe the RUCKUS ICX 8200 LED patterns. TABLE 9 LINK/ACT (Link/Activity) Management Port Status LED LED State Status of Hardware Recommended Action Off (no light) Not cabled or no link.
  • Page 75 No action required. Steady amber Packet errors have been detected on the port. No action required. Blinking amber-green Port is disabled by UDLD, LACP, or other error. No action required. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 76 (with power cord connected) Blinking red Power supply has detected an over-current condition. The warning can be cleared by using the following CLI command: clear chassis unit-id id ps-device id led RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 77: Performing A Factory Reset

    The following commands can be especially helpful in monitoring the health status of various device components. For details about these commands, refer to the RUCKUS FastIron Management Configuration Guide: • show chassis • show system RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 78: Monitoring Power And Cooling

    Fan 1 ok, speed (auto): [[1]]<->2 Fan 2 ok, speed (auto): [[1]]<->2 Fan controlled temperature: 35.5 deg-C Fan speed switching temperature thresholds: Speed 1: NM<----->56 deg-C Speed 2: 48<-----> 69 deg-C (shutdown) RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 79 Slot 1 Current Temperature: 25.0 deg-C (Sensor 1), 30.0 deg-C (Sensor 2), 35.5 deg-C (Sensor 3), 37.0 deg-C (Sensor 4), 33.0 deg-C (Sensor 5) Warning level..: 55.0 deg-C Shutdown level..: 69.0 deg-C Boot Prom MAC : c0c5.207e.9cd2 Management MAC: c0c5.207e.9cd2 ICX8200-48PF2 Router# RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 80 Monitoring the Device Monitoring Power and Cooling RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 81: Power Supplies

    The power supplies in the RUCKUS ICX 8200-48PF2 switch chassis can be removed and replaced without special tools. The device can continue operating during the replacement. The RUCKUS ICX 8200-48PF2 switch supports an AC power supply with nonport-side air exhaust. This unit moves the air from the port side to the nonport side of the device.
  • Page 82: Precautions Specific To Power Supplies

    Replacing a Power Supply When installing or replacing a power supply unit, keep in mind that a power supply for the RUCKUS ICX 8200-48PF2 can be swapped in or out while the device is running. The remaining power supply provides enough power for the device.
  • Page 83 When the RUCKUS ICX 8200-48PF2 switch is powered on, the LEDs on the power supply rear panel should light up green to confirm that the power supply is correctly installed and supplying power.
  • Page 84: Grounding The Ruckus Icx 8200-48Pf2 Switch

    Crimp a grounding lug to a grounding wire of at least 10 American Wire Gauge (AWG). The 10 AWG wire and grounding lug should be crimped together using a proper tool. Attach the 10 AWG stranded copper wire to the grounding terminal on the RUCKUS ICX 8200 switch using the screw and lock washer included in the accessory kit.
  • Page 85: Fan Assemblies

    The fan assemblies in the RUCKUS ICX 8200-48PF2 switch chassis can be removed and replaced without special tools. The device can continue operating during the replacement.
  • Page 86: Precautions Specific To Fan Assemblies

    Replacing a Fan Assembly When installing or replacing a fan assembly unit, keep in mind that a fan assembly for the RUCKUS ICX 8200-48PF2 can be swapped in or out while the device is running. The remaining fan assembly provides enough airflow for the device.
  • Page 87 If you do not install a fan assembly or power supply in a slot, you must keep the slot filler panel in place. If you run the chassis with an uncovered slot, the system will overheat. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 88 Fan Assemblies Inserting a New Fan Assembly RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 89: Ruckus Icx 8200 Specifications

    Stackable up to 12 switches per stack, chassis-mountable (1U) in a standard 4-post rack Power Supplies Fixed AC power supply Dual redundant, hot-swappable power supplies supported with 920 W AC (ICX 8200-48PF2) Fan Assemblies Dual redundant, hot-swappable fan assemblies (ICX 8200-48PF2)
  • Page 90: Leds

    LEDs System Component Description Maximum Ports Supported 1 GbE RJ-45 Ports 10/100/1000 RJ-45 port 48 (ICX 8200-48, ICX 8200-48P, ICX 8200-48PF, ICX 8200-48PF2) 24 (ICX 8200-24, ICX 8200-24P) 8 (ICX 8200-C08PF) Ethernet Management Port 10/100/1000 Mbps RJ-45 port LEDs System Component...
  • Page 91: Environmental Requirements

    ICX 8200-48P: 41.0 dBA ICX 8200-48PF: 41.0 dBA ICX 8200-48PF2: 51.0 dBA ICX 8200-C08PF: Fanless Power Supply Specifications (per PSU) The RUCKUS ICX 8200-48PF2 switch is the only model that supports a hot-swappable power supply. Power Supply Maximum Input Voltage Input Line...
  • Page 92: Power Supply Hold-Up Times

    ICX 8200-24P 37 W 36.5 W 1 x 525 W AC 126.28 BTU/hr 124.58 BTU/hr ICX 8200-C08PF 18.1 W 18 W 1 x 240 W AC 61.78 BTU/hr 61.44 BTU/hr RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 93: Power Consumption (Maximum Configuration)

    ICX 8200-C08PF 10 GbE 2 (slot 2) 1/10 GbE SFP+ stacking/uplink ports, compatible with optical transceivers, or direct attached copper cable 1 GbE 8 (slot 1) RJ-45 PoE+ ports, 10/100/1000 Mbps RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 94: Serial Port Specifications (Pinout Usb Type-C)

    Reserved Not used USB-C_GND Ground Serial Port Specifications (Pinout RJ-45) Signal Description Not supported Not supported UART1_TXD Transmit data to ICX Logic ground Not supported UART1_RXD Receive data from ICX RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 95: Serial Port Specifications (Protocol)

    CNS 15936-1 (BSMI) (Taiwan) (Class A) • KS C 9832 (South Korea) (Class A) • KS C 9835 (South Korea) • TCVN 7189 / TCVN 7317 (Vietnam) (Class A) • EN 61000-3-2 • EN 61000-3-3 RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 96: Regulatory Compliance (Safety)

    SJ/T 11363-2006 Requirements for Concentration Limits for Certain Hazardous Substances in EIPs (China) • SJ/T 11364-2006 Marking for the Control of Pollution Caused by EIPs (China) • CNS 15663 (BSMI) (Taiwan) RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 97: Regulatory Statements

    Maschinenlärminformations-Verordnung - 3. GPSGV, der höchste Schalldruckpegel beträgt 52 dB(A) gemäss EN ISO 7779. English translation of above statement Machine noise information regulation - 3. GPSGV, the highest sound pressure level value is 52 dB(A) in accordance with EN ISO 7779. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 98: Japan (Vcci)

    Class A device (Broadcasting Communication Device for Office Use): This device obtained EMC registration for office use (Class A), and may be used in places other than home. Sellers and/or users need to take note of this. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 99: China

    English translation of above statement This is a Class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 100: Bsmi Statement (Taiwan)

    BSMI Statement (Taiwan) English translation of above statement Warning: To avoid electromagnetic interference, this product should not be installed or used in a residential environment. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 101: Cautions And Danger Notices

    Pour une utilisation en intérieur uniquement. Le commutateur, les alimentations et tous les câbles connectés ne sont pas conçus pour une utilisation en extérieur. PRECAUCIÓN Sólo para uso en interiores. El interruptor, las fuentes de alimentación y todos los cables conectados no están diseñados para uso en exteriores. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 102 Utilisez les vis mentionnées dans les instructions. L'utilisation de vis plus longues peut endommager l'appareil. MISE EN GARDE PRECAUCIÓN Utilice los tornillos especificados en el procedimiento. Si utiliza tornillos de mayor longitud, podría dañar el dispositivo. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 103 à une source d’alimentation. PRECAUCIÓN Los proveedores de energía son deslizables por calor. Sin embargo deben insertarse o extraerse sin ningún cable de alimentación conectado a la fuente de alimentación para evitar daños. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 104 Compare esta suma con el límite nominal para el circuito. Las capacidades nominales de corriente máximas están generalmente impresas en los instrumentos, cerca de los conectores de corriente de entrada. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 105 Vérifiez que le bâti ou le support abritant le dispositif est bien fixé afin qu'il ne devienne pas instable ou qu'il ne risque pas de tomber. Verifique que el bastidor o armario que alberga el instrumento está asegurado correctamente para evitar que pueda hacerse inestable o PRECAUCIÓN que caiga. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 106 Para prevenir daños al chasis y a los componentes, nunca intente levantar el chasis usando las asas de la fuente de alimentación o del ventilador. Tales asas no han sido diseñadas para soportar el peso del chasis. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 107: Danger Notices

    à grande vitesse. PELIGRO Procure no insertar los dedos accidentalmente en la bandeja del ventilador cuando esté desmontando el chasis. El ventilador podría estar girando a gran velocidad. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 108 Débranchez le cordon d'alimentation de toutes les sources d'alimentation pour couper complètement l'alimentation du dispositif. PELIGRO Para desconectar completamente la corriente del instrumento, desconecte el cordón de corriente de todas las fuentes de corriente. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 109 Rayonnement de laser. Ne regardez pas directement avec les instruments optiques. Produits de laser de la classe 1M. PELIGRO Radiacion de Laser. No vea directamente con Instrumentos Opticos. Clase 1M de Productos de Laser. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...
  • Page 110 Utilice sólo transceptores ópticos aprobados por RUCKUS y que cumplan con las normas IEC 60825 y EN60825, y con los estándares de rendimiento Clase 1 de FDA definidos en el subcapítulo I de 21 CFR. Los productos ópticos que no cumplan con estos estándares pueden emitir luz dañina para los ojos. RUCKUS ICX 8200 Switch Hardware Installation Guide Part Number: 53-1005735-01...

Table of Contents