Operation
NOTE: Use lower radiator hose heater only in its desig-
nated location. Incorrect use can damage the engine.
Proceed as follows when operating a unit equipped with
a lower radiator hose heater.
1. Verify unit is level to maintain proper orientation of
heater while in operation.
2. Verify cooling system is full of the correct mixture of
water and engine coolant before each use.
3. Use only an undamaged, outdoor rated, three-
prong grounded 120VAC extension cord with a
minimum amperage rating of 10A. Connect cord to
a properly grounded 120VAC, GFCI outlet.
4. Before starting engine, unplug extension cord from
power first, then unplug heater cord set from exten-
sion cord.

Tandem Tow (If Equipped)

See
Figure
3-12. The tandem tow hitch option (A) allows
the operator to tow a second MLT6 Light Tower in series
behind a unit equipped with a hitch.
IMPORTANT NOTE: Never tow more than two units
at once.
C
Figure 3-12. Tandem Tow
Connect any trailer wiring to the unit in front (B).
Check for proper operation of the directional and
brake lights.
Connect the towing chains to the tie down locations
(C).
Avoid sharp turns when towing. Do not cross any
obstacles more than 12 in (30.5 cm) deep.
Tandem tow speeds:
a. Paved highway—45 mph (72 km/h)
b. Graded gravel—25 mph (40 km/h)
c. Cross country—15 mph (24 km/h)
32
C
A
B
004770

Telemetry (If Equipped)

The digital telemetry option enables the operator to
remotely monitor the unit fuel level. A transmitter inside
the engine compartment sends real time equipment sta-
tus information to the user via cellular or satellite connec-
tion.

Spark Arrester (If Equipped)

A spark arrester, installed on the exhaust, may be
required by code in certain municipalities. Verify with the
local authority having jurisdiction to determine if a spark
arrester must be installed on the unit before operation.
Lowering the Mast—Manual
Winch
WARNING
Burn hazard. Lamps become extremely hot
while in use. Allow 10–15 minutes for cooling
before handling or lowering mast. Touching a
hot lens or fixture can cause severe burns.
WARNING
Personal Injury. Stop immediately if the mast hangs
up or the winch cable develops slack. Excess slack
could cause the mast to collapse, resulting in personal
injury or equipment damage.
1. Shut down lights and engine. See
the
Unit.
2. Lower mast.
3. Use winch handles to collapse mast to lowest posi-
tion. Verify electrical cord does not get caught in, or
pinched by, mast while it is being lowered.
IMPORTANT NOTE: Contact a GMP ASD immedi-
ately if mast hangs up or winch cable develops slack.
4. See
Figure
3-13. If unit will be moved, rotate mast
so lights face rear of the unit.
Figure 3-13. Stowed (Travel) Position