Download Print this page

Wiring Instructions - M-system R30MS4 Instruction Manual

Potentiometer input module

Advertisement

WIRING INSTRUCTIONS

■ TORQUE
Wiring screw for separable terminal: 0.5 N·m
Fixing screw for separable terminal: 0.5 N·m
■ SOLDERLESS TERMINAL unit: mm
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solder-
less terminals with insulation sleeve do not fit.
Recommended manufacturer: Japan Solderless Terminal
MFG.Co., Ltd., Nichifu Co., Ltd.
Applicable wire size: 0.25 – 0.75 mm
3 max.
■ HOW TO REMOVE SEPARABLE SCREW TERMINAL
The terminal block is separable in two pieces. Evenly loos-
en two screws on top and bottom of the terminal block to
separate.
2
3.2 dia.
12 max.
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
CONFIGURATOR SOFTWARE SETTING
With configurator software, settings shown below are avail-
able. Refer to the software manual of R30CFG for detailed
operation.
■ CHANNEL INDIVIDUAL SETTING
ITEM
USABLE RANGE
Unused setting
CH enabled
CH disabled
Fine zero adjustment
-320.00 – +320.00
Fine gain adjustment -320.00 – +320.00
Scaled range Zero
-32 000 – +32 000
Scaled range Span
-32 000 – +32 000
■ CHANNEL BATCH SETTING
ITEM
USABLE RANGE
Conversion rate
80 ms
40 ms
20 ms
10 ms
Simulate input
Normal input
Simulated data
R30MS4
DEFAULT
SETTING
CH enabled
0.00
0.00
0
10 000
DEFAULT
SETTING
80 ms
Normal input
EM-9004 Rev.1 P. 5 / 5

Advertisement

loading