ASSEMBLE AND MOUNT THE RETURN AND THROTTLING VALVE

FIGURE 2. Assembly of the Throttling and Electric Return Valve
1. Assemble the Electronic Recirculation Valve (P/N 334-0001-081) and throttling valve assembly as shown in
Figure 2 on page 12.
2. Mount the throttling valve to the center rack mounting bracket (P/N 107-0172-753) using two U-bolts with 1/4"
washer and 1/4" lock nuts.
3. Loop the U-bolts over the center M200 tee and secure to bracket.
NOTE:
Assemble with the cable of the electronic recirculating valve facing down and the handle of the
throttling valve pointing away from the return valve when in the open position.
4. Once assembly is complete, mount the bracket to the center rack at the rear of the machine using the existing
hardware.