5.4.2.1
Application example
You want to view a rotating object with external triggering.
The viewing area or the mark of the rotating object is outside or not perfectly within your field of
view. With the phase shift / delay of the flash triggering, you can let the field of view / the marking
move optically around the axis of rotation to the ideal position.
5.5

Synchronised output / trigger output

The output signal is output via the "Ext. triggering / signal output" socket.
5.6

Movement analysis

Set the stroboscope ideally as described in chapter 5.3.
Now slowly press the "+ / - rotary switch". This triggers a slow motion effect that allows
you to view the movement more closely.
6

Notes

6.1

Duration of use

The maximum time of use of the stroboscope per measurement should not exceed the following
times. The pause between measurements should be at least 10 minutes.
Flash frequency
<2000 RPM
2001 ... 3600 RPM
3601 ... 8000 RPM
>8000 RPM
6.2

Replacing the flash lamp

The flash lamp must be replaced if the unit flashes erratically at a set flash frequency of more
than 3600. The lamp should be replaced by a qualified technician.
Switch off the instrument and disconnect it from the power supply.
Wait 15 minutes to allow all electronic components to discharge.
Loosen the four screws of the lamp cover on the front side.
Remove the protective glass and the reflector.
Detach the flash lamp from the base.
Insert a new flash lamp.
Mount the reflector and the protective glass.
Fasten the screws of the front cover.
Attention!
Do not touch the flash lamp with your fingers. Use protective gloves.
Duration
4 hours
2 hours
60 minutes
30 minutes